The Impact of Above-sheathing Ventilation on the Thermal and Moisture Performance of Steep-slope Residential Roofs and Attics

نویسنده

  • William Miller
چکیده

Field studies were conducted on several attic assemblies having stone-coated metal shake roofs with and without infrared blocking color pigments (IrBCPs) and with and without above-sheathing ventilation. The combination of increased solar reflectance and above-sheathing ventilation reduced the heat flow penetrating the attic floor by 70% as compared with the heat flow penetrating the attic floor of a roof with conventional asphalt shingles. The venting strategy also eliminated the heating penalty associated with a reflective roof as compared with that of a dark heat-absorbing shingle roof.

منابع مشابه

Effect of Dry Wall Coating on Energy Consumption in Buildings Humid and Temperate Climate

Nowadays, ignoring the climatic features of the region and imitating other parts of the country, the choice of form and interviewing besides transforming the faces of buildings and towns and avoiding the indigenous identity of the area has made residents comfortable. The use of cement blocks and the application of roofs by metal sheets and the application of waterproofing and metal sheets in th...

متن کامل

Study of thermal performance of building roofs in the city of Tehran

The design of a building can provide the highest thermal comfort in the interior without any mechanical equipment and save energy to a large extent. The roof of a building is an important part for thermal loss. This research studies the thermal performance of 14 conventional roof structures in Tehran city by using designbuilder 4.5. It is found that the polystyrene block performs best compared ...

متن کامل

Impacts of Ventilation Ratio and Vent Balance on Cooling Load and Air Flow of Naturally Ventilated Attics

The impacts of ventilation ratio and vent balance on cooling load and air flow of naturally ventilated attics are studied in this paper using an unsteady computational fluid dynamics (CFD) model. Buoyancy-driven turbulent ventilations in attics of gable-roof residential buildings are simulated for typical summer conditions. Ventilation ratios from 1/400 to 1/25 combined with both balanced and u...

متن کامل

Investigation on thermal behavior of common types of roofs in buildings using computational fluid dynamics method

In this study, the influence of type and structure of different roofing systems were investigated using computational fluid dynamic method. The considered roofing systems include beam and block types (clay brick, light weight concrete block, polystyrene) and Uboot slab which were designed for 6m and 8m span. To simulate the fluid flow and heat transfer, the computational fluid dynamic method wa...

متن کامل

Numerical Investigation of Roofing Materials Effect on Solar Heat Gain in Different External Conditions

In this study, the thermal performance of three kinds of roofs with different heat capacity and thermal conductivity under different external conditions has been investigated using a numerical method. For this purpose, the combined solar radiation, conduction and convection heat transfer were calculated implicitly in terms of a one-dimensional finite difference method. Different high and low so...