Flow effects in balanced steady state free precession imaging.

نویسندگان

  • M Markl
  • M T Alley
  • C J Elkins
  • N J Pelc
چکیده

An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady-state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various through-plane flow waveforms and rates were modeled numerically considering factors such as the excitation slice profile and both in- and out-flow effects. Phantom measurements in an experimental setup that allowed the assessment of SSFP signal properties as a function of frequency offset and flow rate demonstrated that the computer simulations provided a suitable description of the effects of flow in SSFP imaging. A volunteer scan was performed to provide in vivo validations. For accurate modeling of SSFP signal intensities it is crucial to include effects such as imperfect slice profiles and, more importantly, "out-of-slice" contributions to the signal. Both simulations and experiments show that there can be considerably large-frequency offset dependent-signal contributions from flowing spins that have already left the imaging slice but still add to the SSFP signal. Although spins leaving the slice do not experience additional RF-excitation, gradient activity is not confined to the region of excitations and the balanced nature of the SSFP imaging gradients allows "out-of-slice" transverse magnetization to contribute to the total SSFP signal, effectively by broadening the slice thickness for flowing spins. This results in a frequency dependence of in-flow related signal enhancement and flow artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrally selective imaging with wideband balanced steady-state free precession MRI.

PURPOSE Unwanted, bright fat signals in balanced steady-state free precession sequences are commonly suppressed using spectral shaping. Here, a new spectral-shaping method is proposed to significantly improve the uniformity of stopband suppression without compromising the level of passband signals. METHODS The proposed method combines binomial-pattern excitation pulses with a wideband balance...

متن کامل

Flow-Insensitive, Motion-Compensated Balanced Steady-State Free Precession Imaging

O. Bieri, J. Leupold, G. Laub, K. Scheffler Department of Medical Radiology, MR-Physics, University of Basel, Basel, Switzerland, Department of Radiology, Section of Medical Physics, Freiburg, Germany, Siemens Medical Solution, Los Angeles, CA, United States Introduction. For conventional balanced steady state free precession b-SSFP pulse sequences employing gradient reversal echoes and short r...

متن کامل

Spoiled & Balanced Gradient Echo Methods

Imaging with spoiled, balanced or nonbalanced gradient echo (GRE) refers to a class of fast imaging sequences that use a dynamic equilibrium or steady state signal for imaging. As originally introduced in 1958 by Carr (1) for NMR spectroscopy, a dynamic equilibrium or steadystate can be established by a train of radio-frequency (RF) excitation pulses interleaved by periods of ‘free precession’,...

متن کامل

Spiral balanced steady-state free precession cardiac imaging.

Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method t...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 2003