Lesion heterogeneity in multiple sclerosis: a study of the relations between appearances on T1 weighted images, T1 relaxation times, and metabolite concentrations.
نویسندگان
چکیده
OBJECTIVES Multiple sclerosis lesions appear as areas of high signal on T2 weighted MRI. A proportion of these lesions, when viewed on T1 weighted MRI, appear hypointense compared with surrounding white matter. These hypointense T1 lesions are thought to represent areas of greater tissue damage compared with the more non-specific, total T2 lesion load. This study aimed to better characterise the properties of high signal T2 lesions with differing appearances on T1 weighted MRI using quantitative MR techniques. METHODS Eleven patients with secondary progressive multiple sclerosis were studied. Two high signal T2 lesions were selected from each patient-one of which appeared hypointense and one isointense on a T1 weighted image. A voxel was positioned around each lesion and for this volume of brain the metabolite concentrations were estimated using proton MR spectroscopy ((1)H-MRS) and the T1 relaxation time within each voxel calculated from a T1 map generated using a multislice technique. RESULTS Compared with isointense T1 lesions, hypointense T1 lesions exhibited a significantly lower absolute concentration of N-acetyl derived metabolites (tNAA) and a significantly higher absolute concentration of myo-inositol (Ins). T1 relaxation time correlated significantly with both tNAA (r=-0.8, p < 0.001) and Ins (r=0.5, p=0. 012). There was no correlation between T1 relaxation times and creatine/phosphocreatine or choline containing compounds. CONCLUSIONS Prolonged T1 relaxation times seem to reflect the severity of axonal damage or dysfunction (inferred by a low tNAA) and possibly also gliosis (inferred by a high Ins) in chronic multiple sclerosis lesions.
منابع مشابه
Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inver-sion recovery T1-weighted MRI
Background: Ultrasmallsuperparamagnetic iron oxide (USPIO) nanoparticles are used as blood pool contrast agent for magnetic resonance angiography and perfusion imaging. Our aim in this study was to investigate the effect of the two coating types of iron oxide nanoparticles on the relationship between nanoparticles concentration and signal intensity (SI) in T1-weighted MR images. Methods : D...
متن کاملThe effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence
Background :Inversion recovery (IR) pulse sequences can generate T1-weighted images with a different range of inversion time (TI) to suppress or null the signal intensity (SI) for a specified tissue. In this study, we aimed to investigate the effect of TI values on the concentration of the contrast agent, which leads to a minimum signal intensity, using an inversion recovery T1-weighted 3-dim...
متن کاملADvanced IMage Algebra (ADIMA): a novel method for depicting multiple sclerosis lesion heterogeneity, as demonstrated by quantitative MRI
BACKGROUND There are modest correlations between multiple sclerosis (MS) disability and white matter lesion (WML) volumes, as measured by T2-weighted (T2w) magnetic resonance imaging (MRI) scans (T2-WML). This may partly reflect pathological heterogeneity in WMLs, which is not apparent on T2w scans. OBJECTIVE To determine if ADvanced IMage Algebra (ADIMA), a novel MRI post-processing method, ...
متن کاملEvolution of multiple sclerosis lesions on serial contrast-enhanced T1-weighted and magnetization-transfer MR images.
BACKGROUND AND PURPOSE Magnetization-transfer imaging is a technique that could provide indirect evidence of the characteristics of multiple sclerosis (MS) lesions. The purpose of this work was to study the evolution of MS lesions on T1-weighted MR images over time and to investigate changes in magnetization-transfer ratio (MTR) values of MS lesions with different initial appearances on contras...
متن کاملT1- Thresholds in Black Holes Increase Clinical-Radiological Correlation in Multiple Sclerosis Patients
BACKGROUND Magnetic Resonance Imaging (MRI) is an established tool in diagnosing and evaluating disease activity in Multiple Sclerosis (MS). While clinical-radiological correlations are limited in general, hypointense T1 lesions (also known as Black Holes (BH)) have shown some promising results. The definition of BHs is very heterogeneous and depends on subjective visual evaluation. OBJECTIVE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 68 5 شماره
صفحات -
تاریخ انتشار 2000