Pseudotumours associated with metal-on-metal hip resurfacing: 10-year Newcastle experience.

نویسندگان

  • Ajay Malviya
  • James P Holland
چکیده

We report the incidence of pseudotumours in a single-surgeon consecutive series of 670 metal-on-metal hip resurfacings performed in the last ten years, with a minimum follow-up of one year. Two cases of pseudotumours have been found and are discussed in detail including metrology and wear analyses of the explanted components. The first was a painless, large synovial cyst in the thigh, secondary to aseptic femoral cup loosening 8 years following hip resurfacing. The second was a painful collection of wear debris in the psoas region at one year post surgery caused by impingement, resulting in eccentric edge wearing. In the first case it was decided to retain the bearing surface; in the second case, conversion to a metal-on-polyethylene hip replacement was performed. In our experience the risk of pseudotumours is low (0.15%) and can be fully explained. In selected cases the bearing surface can be retained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours.

The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for...

متن کامل

In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours

OBJECTIVES Pseudotumours (abnormal peri-prosthetic soft-tissue reactions) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have been associated with elevated metal ion levels, suggesting that excessive wear may occur due to edge-loading of these MoM implants. This study aimed to quantify in vivo edge-loading in MoMHRA patients with and without pseudotumours during functional activ...

متن کامل

Pseudotumours associated with metal-on-metal hip resurfacings.

We report 17 patients (20 hips) in whom metal-on-metal resurfacing had been performed and who presented with various symptoms and a soft-tissue mass which we termed a pseudotumour. Each patient underwent plain radiography and in some, CT, MRI and ultrasonography were also performed. In addition, histological examination of available samples was undertaken. All the patients were women and their ...

متن کامل

Hip resurfacings revised for inflammatory pseudotumour have a poor outcome.

Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements. We identified 53 hi...

متن کامل

Asymmetrical hip loading correlates with metal ion levels in patients with metal-on-metal hip resurfacing during sit-to-stand.

The occurrence of pseudotumours following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. Measuring ground reaction force is a simple method of collecting information on joint loading during a sit-to-stand (STS). We investigated vertical ground reaction force (VGRF) asymmetry during sit-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 75 4  شماره 

صفحات  -

تاریخ انتشار 2009