Dominant frequency content of ocular microtremor from normal subjects

نویسندگان

  • Ciaran Bolger
  • Stana Bojanic
  • Noirin F. Sheahan
  • Davis Coakley
  • James F. Malone
چکیده

Ocular microtremor (OMT) is a high frequency tremor of the eyes present during fixation and probably related to brainstem activity (Coakley, D. (1983). Minute eye movement and brain stem function. CRC Press, FL.). Published observations on the frequency of OMT have varied widely. Ocular microtremor was recorded in 105 normal healthy subjects using the Piezoelectric strain gauge technique. The dominant frequency content of a signal was determined using the peak counting method. Values recorded ranged from 70 to 103 Hz, the mean frequency being 83.68 Hz (S.D. +/- 5.78 Hz).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of age on ocular microtremor activity.

BACKGROUND Ocular microtremor (OMT) is a high-frequency tremor of the eyes. It is present in all individuals and is related to brainstem activity. The OMT signal appears as an irregular oscillatory movement with intermittent burst-like components. The clinical interest in OMT has centered on its use in the assessment of the comatose patient, with broad agreement among authors of its prognostic ...

متن کامل

Ocular microtremor (OMT): a new neurophysiological approach to multiple sclerosis, by C. Bolger, S. Bojanic, N. Sheahan, J. Malone, and D. Coakley. J Neurol Neurosurg Psychiatry 68:639-42, 2000.

Using a piezoelectric transducer, the frequency and pattern of ocular microtremor (OMT) between 50 normal subjects and 50 patients with multiple sclerosis were compared. Controls were age matched. All records were analysed blindly. The frequency of OMT in the normal group was 86 (SD 6) Hz, which was significantly different from that of the multiple sclerosis group (71 (SD) 10 Hz, p<0.001). Thos...

متن کامل

Speckle interferometric sensor to measure low-amplitude high frequency Ocular Microtremor (OMT)

Ocular microtremor (OMT) is a physiological high frequency (up to 150Hz) low amplitude (150-2500nm) involuntary tremor of the human eye. It is one of the three fixational ocular motions described by Adler and Fliegelman in 1934 as well as microsaccades and drift. Clinical OMT investigations to date have used eye-contacting piezoelectric probes or piezoelectric strain gauges. Before contact can ...

متن کامل

Ocular microtremor: a tool for measuring depth of anaesthesia?

Ocular microtremor (OMT) is a fine high frequency tremor of the eyes caused by extra-ocular muscle activity stimulated by impulses emanating in the brain stem. Several studies have shown that the frequency of this tremor is reduced in patients whose consciousness is reduced by anaesthesia or head injury. Therefore, OMT may possibly be used to determine depth of anaesthesia. Twenty-two unpre-med...

متن کامل

Ocular microtremor in patients with idiopathic Parkinson's disease.

Abnormalities in the oculomotor control mechanism of patients with idiopathic Parkinson's disease are well recognised. In this study the effect of Parkinson's disease on tonic output from oculomotor nuclei was studied by using oculomicrotremor as an index of such output. Oculomicrotremor readings were taken from 22 parkinsonian patients and 22 normal healthy volunteers using the piezoelectric s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1999