Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.

نویسندگان

  • Frederick G Strathmann
  • Michael M Ka
  • Petrie M Rainey
  • Geoffrey S Baird
چکیده

We investigated the use of serum samples from BD Vacutainer rapid serum tubes (RSTs; BD, Franklin Lakes, NJ) to reduce undetermined interferences contributing to false-positive immunoassay results in heparin plasma samples. Patients being evaluated for suspected myocardial infarction had specimens drawn into an RST in addition to the standard lithium-heparin plasma separator tube (PST). We measured 28 separate analytes in both specimens using immunoassay, electrochemical, and spectrophotometric methods. Higher results were observed in some PST specimens tested for troponin I, creatine kinase-MB isoenzyme, human chorionic gonadotropin, and thyroid-stimulating hormone. These discrepancies were investigated by repeating analyses after recentrifugation of both specimens. Reanalysis gave results for the PST specimens that were lower and agreed well with initial results from RSTs, suggesting false-positive rates of 10.8% for troponin I and about 2% for each of the other 3 analytes. Overall, specimens collected in RSTs had fewer false-positive immunoassay results than specimens collected in plasma separator tubes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Falsely Increased hCG in Patients with High Leukocyte Counts

Falsely increased plasma troponin (Tn) I and T results have been reported for several Tn methods, including the Beckman Coulter UniCel DxI AccuTnI assay (Beckman Coulter, Chaska, MN) (1–3). We and others have also observed falsely increased human chorionic gonadotropin (hCG) using the Beckman Coulter Access Total hCG on the UniCel DxI (1). These false increases were identified by the finding of...

متن کامل

Falsely increased HCG in patients with high leukocyte counts.

Falsely increased plasma troponin (Tn) I and T results have been reported for several Tn methods, including the Beckman Coulter UniCel DxI AccuTnI assay (Beckman Coulter, Chaska, MN) (1–3). We and others have also observed falsely increased human chorionic gonadotropin (hCG) using the Beckman Coulter Access Total hCG on the UniCel DxI (1). These false increases were identified by the finding of...

متن کامل

Evaluation of the BD Vacutainer® RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study

INTRODUCTION Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum ...

متن کامل

Performance characteristics of the UniCel DxI 800 immunoassay for the maternal serum quadruple test, including median values for each week of gestation, in Korean women.

BACKGROUND Maternal serum prenatal quadruple screening includes testing for alpha-fetoprotein (AFP), human chorionic gonadotrophin (hCG), unconjugated estriol (uE3), and dimeric inhibin A (DIA). We evaluated quadruple screening using an automated platform and looked for any ethnic differences in the median values of each marker. METHODS We measured the concentrations of each quadruple test an...

متن کامل

Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2s.

BACKGROUND Measurement of 25(OH)D has evolved rapidly, with an increased number of high-throughput automated immunoassays becoming available in recent years. The aim of this study was to fully evaluate six commercially available automated 25(OH)D immunoassays, including 2 newly available (Beckman Coulter) and one recalibrated (Siemens) assay. Comparisons were made to specifically identify the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 136 2  شماره 

صفحات  -

تاریخ انتشار 2011