Comparison of the Bactec 9240 and BacT/Alert blood culture systems for evaluation of placental cord blood for transfusion in neonates.

نویسندگان

  • Stefan Riedel
  • Alan Junkins
  • Paul D Stamper
  • Gretchen Cress
  • John A Widness
  • Gary V Doern
چکیده

The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system (P < 0.001). When concentrated red cells and whole blood were compared, the Bactec system detected bacterial growth consistently sooner than the BacT/Alert system in all seeded bacteria except Staphylococcus species in whole blood. The median lengths of time to detection (LTD) for whole blood and concentrated cells in BacT/Alert were 18.7 h and 18.5 h, respectively. The median LTD for the same blood fractions using the Bactec system were 16.05 h and 15.64 h. These differences in LTD by blood culture system and sample type were statistically significant (whole blood, P = 0.0449; concentrated cells, P = 0.0037). Based on the results of our study, we recommend the use of either concentrated red cells or whole blood for sterility testing in UCB samples. In our laboratory, the Bactec system compared to the BacT/Alert system was the superior method for rapid detection of bacterial contaminants in cord blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...

متن کامل

Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

In a collaborative study at three university hospitals, the recovery of microorganisms and the speed of detection of microbial growth by the BacT/Alert (Organon Teknika Corporation, Durham, N.C.) and BACTEC 660/730 (Becton-Dickinson Diagnostic Instrument Systems, Sparks, Md.) nonradiometric blood culture systems were compared. A total of 5,918 comparisons were made between BacT/Alert aerobic an...

متن کامل

Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

A total of 7,190 blood culture sets were obtained from adult patients with a suspected bloodstream infection. A 20-ml sample of blood was distributed equally between the aerobic FAN bottle which was monitored in the BacT/Alert system and a Plus Aerobic/F bottle which was monitored in the BACTEC 9240 system. A total of 988 positive cultures were obtained from 483 patients; however, only 453 posi...

متن کامل

Apparent culture-negative prosthetic valve endocarditis caused by Peptostreptococcus magnus.

In two patients with prosthetic valve endocarditis due to Peptostreptococcus magnus, blood cultures in the BacT/Alert and BACTEC 9240 systems were signal negative. The capability of the BacT/Alert system to detect various Peptostreptococcus species was assessed. P. magnus and P. anaerobius could not be detected, and subcultures remained negative. The growth in conventional media of these two sp...

متن کامل

Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems.

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 47 6  شماره 

صفحات  -

تاریخ انتشار 2009