Driveline Infection in Ventricular Assist Devices and Its Implication in the Present Era of Destination Therapy
نویسندگان
چکیده
Advances in mechanical circulatory support devices provided the technology to develop long-term, implantable left ventricular assist devices as bridge to transplant, destination therapy, and in a lesser group of patients, as bridge to recovery. Despite the benefits from this innovative therapy, with their increased use, many complications have been encountered, one of the most common being infections. With the driveline acting as a portal to the exterior environment, an infection involving this structure is the most frequent one. Because patients with destination therapy are expected to receive circulatory support for a longer period of time, we will focus this review on the risk factors, prevention, and treatment options for driveline infections.
منابع مشابه
FDG PET/CT imaging for LVAD associated infections.
HEART FAILURE IS A MAJOR CAUSE OF MORBIDITY AND MORTALITY, particularly among patients with advanced disease and no access to cardiac transplantation. Owing to the constant shortage of donor hearts, the role of left ventricular assist device (LVAD) has been expanding in the management of these patients both as a bridge to transplantation and as a destination therapy (i.e., alternative to transp...
متن کاملLeft ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients.
OBJECTIVES To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD). BACKGROUND Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice. METHODS A retrospective chart review was conducted on 68...
متن کاملVeraFlo Negative Pressure Wound Therapy with Household Bleach for Refractory Driveline Infection in a Patient with Left Ventricular Assist Device
Driveline infections and sepsis are amongst the most common causes of morbidity and mortality in a patient with a left ventricular assist device. In this case, we present a patient with a multi drug resistant pseudomonas aeruginosa driveline exit site infection. Initially, it was treated with dual antibiotics, followed by surgical debridement utilizing Dakin’s solution irrigation and standard n...
متن کاملSPECT/CT Assessment of Infected Intracardiac Devices With and Without Attenuation Correction.
Left ventricular assist devices (LVADs) provide the ability to maintain cardiac output and sustain life as a bridge to transplantation, definitive therapy, or a permanent decision. We present a case of LVAD drive infection that was differentiated from pump infection by the use of attenuation-corrected and non-attenuation-corrected CT, along with correlation with the planar images. Clinically, t...
متن کاملSdrF, a Staphylococcus epidermidis Surface Protein, Contributes to the Initiation of Ventricular Assist Device Driveline–Related Infections
Staphylococcus epidermidis remains the predominant pathogen in prosthetic-device infections. Ventricular assist devices, a recently developed form of therapy for end-stage congestive heart failure, have had considerable success. However, infections, most often caused by Staphylococcus epidermidis, have limited their long-term use. The transcutaneous driveline entry site acts as a potential port...
متن کامل