NATIONAL PHYSICAL LABORATORY MCNP Calculations of Correction Factors for Radionuclide Neutron Source Emission Rate Measurements using the Manganese Bath by
نویسنده
چکیده
The manganese bath method for measuring the neutron emission rate of radionuclide sources requires corrections to be made for emitted neutrons which are not captured by manganese nuclei. The Monte Carlo particle transport code MCNP has been used to calculate the fractions of neutrons that escape from the boundaries of the tank, that are captured by the steel cavity in which the source is housed, and that are captured by fast neutron reactions in oxygen and sulphur in the solution. A comparison has been made with the calculations from the in-house transport codes, and the measurements with the long counter, which highlighted a number of disagreements. These have been investigated and satisfactorily explained. Validation work has also been performed to demonstrate the reliability of the model. In future, the MCNP model will be used, in place of the in-house codes and the long counter, to calculate the correction factors.
منابع مشابه
NATIONAL PHYSICAL LABORATORY Calibration and Monte Carlo Modelling of the NPL Long Counters
An extensive programme was successfully carried out during the 1995 to 1998 NMS programme to recalibrate and model by Monte Carlo simulations the characteristics of two NPL long counters that are routinely used to standardise neutron fluences [Ta98,Ta00] for neutron energies above 500 keV. The present work is a continuation of it in that the counters responses and effective centres have been me...
متن کامل-
Neutron dose-equivalent buildup factors were calculated for point isotropic neutron sources irradiating infinite slablike shields of lead, iron and water using the MCNP code. The factors are presented for some source neutron energies in the range from 0.025 eV to 14 MeV, and for shield thicknesses from 0.5 to 10 mfp. Since the MCNP code considers all kinds of neutron interactions with matter, a...
متن کاملNeutron Detection Time Distributions of Multisphere LiI Detectors And AB Remmeter at A 20-MeV Electron Linac
Neutron detection time distribution is an important factor for the dead-time correction for moderator type neutron detectors used in pulsed radiation fields. Measurements of the neutron detection time distributions of multisphere LiI detectors (2Ó, 3Ó, 5Ó, 8Ó, 10Ó and 12Ó in diameter) and AB remmeter were made inside a ANL 20-MeV electron Linac room. Calculations of the neutron detection time d...
متن کاملبررسی قابلیت استفاده از رآکتورMNSR اصفهان در نوترونتراپی با بور به کمک شبیهسازی MCNP
One of the important neutron sources for Boron Neutron Capture Therapy (BNCT) is a nuclear reactor. It needs a high flux of epithermal neutrons. The optimum conditions of the neutron spectra for BNCT are provided by the International Atomic Energy Agency (IAEA). In this paper, Miniature Neutron Source Reactor (MNSR) as a neutron source for BNCT was investigated. For this purpose, we designed a ...
متن کاملThe effect of source shield on landmine detection
Background: Several landmine detection methods, based on nuclear techniques, have been suggested during the recent years. Neutron energy moderation, neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are nuclear-based methods used for landmine detection. The aim of this study is to use backscattered neutron for landmine detection. Materials ...
متن کامل