A Novel Approach for Reducing Dental Filling Artifact in CT-Based Attenuation Correction of PET Data

نویسندگان

  • M. Abdoli
  • M. R. Ay
  • A. Ahmadian
  • N. Sahba
  • H. Zaidi
چکیده

Reliable attenuation correction methods in PET require accurate determination of the attenuation map (μmap), which represents the spatial distribution of linear attenuation coefficients (LACs) at 511 keV for the region under study. Since CT image pixel intensities are directly related to the LAC of the corresponding tissue calculated from the effective CT energy, the μmap at 511 keV can be directly generated from the CT images. The presence of high density dental fillings material in head and neck CT imaging is known to generate strong streak artifacts in the μmap which will likely propagate to the resulting PET images during CT-based attenuation correction (CATC). The purpose of this work is to develop a fast approach for reduction of dental filling artifacts in the generated μmap. Currently available sinogram based metal artifact reduction (MAR) algorithms are based on correction of raw data sinograms which are huge files usually stored in proprietary format not generally disclosed by manufacturers and thus are not straightforward to handle. Our method uses the concept of virtual sinograms for implementation of MAR, which are produced by forward projection of CT images in Dicom format. The projection data affected by metallic objects are detected in the sinogram space by segmentation of metallic objects in the CT image followed by forward projection of the metal-only image. Thereafter the affected projections are replaced by interpolated values from adjacent projections using the spline interpolation technique. The algorithm was applied to a dedicated phantom experiment scanned before and after metal insertion, where the corrected and non-corrected μmaps were compared to the artifact-free μmap. It was observed that by using this fast method, the mean relative error in regions close to metallic objects is ~35% without correction and decreases to ~5% after correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Comparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data

Introduction:  The  advent  of  dual-modality  PET/CT  scanners  has  revolutionized  clinical  oncology  by  improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of  CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates  a noise-free  attenuation  map  (6map).  CTAC  methods  include  scaling,  s...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل