C1-c2 pedicle screw fixation for treatment of old odontoid fractures.
نویسندگان
چکیده
Nonunion and C1-C2 instability of odontoid fractures usually result from delayed diagnosis and inappropriate treatment. However, the available treatment options for odontoid fractures remain controversial. The authors evaluated the effectiveness of internal screw fixation via the C1 and C2 pedicle in cases of old odontoid fractures. This retrospective study included 21 patients with old odontoid fractures (13 men and 8 women; mean age, 46.5 years; range, 24-69 years). Internal screw fixation via the C1 and C2 pedicle was performed in all patients. Fracture reduction and C1-C2 fusion were assessed with imaging. The neck pain visual analog scale score and cervical spinal cord functional Japanese Orthopaedic Association score (for those who had cervical spinal cord injury) were used to evaluate the effectiveness of treatment. Postoperative complications were recorded. Postoperative imaging showed that the C1-C2 dislocation was satisfactorily repositioned in all patients. Bone fusion was observed 1 year after surgery in all patients. No loosening or breaking of internal fixation occurred. The preoperative neck pain visual analog scale score was 5.9±1.5 and improved significantly to 1.8±0.8 after surgery (P<.001). The Japanese Orthopaedic Association score in patients with cervical spinal injury (n=14) was 9.2±1.9 and also significantly improved to 13.8±1.9 at the last follow-up examination (P<.001), with an average improvement rate of 61.0%. No iatrogenic vertebral artery injury or severe spinal cord injury occurred. Screw fixation via the C1 and C2 pedicle was found to be an effective and safe surgical approach for the treatment of old odontoid fractures with C1-C2 dislocation or instability.
منابع مشابه
Surgical treatment of odontoid fractures with C1 hook and C2 pedicle screw construct.
A number of approaches have been attempted to address the treatment of acute odontoid fractures, spanning from conservative treatment with an external orthotic device to posterior C1-C2 arthrodesis or anterior screw fixation. The current report describes stabilisation of such fractures with a C1 supralaminar hook and a C2 pars interarticularis screw construct. Two patients with odontoid fractur...
متن کاملBiomechanical evaluation of four different posterior screw and rod fixation techniques for the treatment of the odontoid fractures.
Problems that screw cannot be inserted may occur in screw-rod fixation techniques such as Harms technique. We compared the biomechanical stability imparted to the C-2 vertebrae by four designed posterior screw and rod fixation techniques for the management of odontoid fractures. A three-dimensional finite element model of the odontoid fracture was established by subtracting several unit structu...
متن کاملTreatment for odontoid fracture with C1 lateral mass and C2 pedicle screws using intraoperative orbic-3-dimensional navigation
Objective: To assess the technical advantages of intraoperative orbic-3-dimensional navigation in the treatment of odontoid fractures. Material and methods: Twelve male patients with type II or rostral type III odontoid fractures were treated with posterior C1LM-C2P screws fixation using the orbic-3D fluoroscopic navigation. The follow-up period ranged from 12 to 24 months with a mean of 19.2 m...
متن کاملComparison of Atlantoaxial Rotation and Functional Outcomes of Two Nonfusion Techniques in the Treatment of Anderson-D'Alonzo Type II Odontoid Fractures.
STUDY DESIGN A retrospective comparative study. OBJECTIVE The aim of this study was to compare the outcomes of anterior screw fixation and posterior temporary-fixation in the treatment of Anderson-D'Alonzo type II odontoid fractures. SUMMARY OF BACKGROUND DATA Posterior C1-C2 temporary-fixation can spare the motion of C1-C2 in the treatment of odontoid fractures. However, it is unknown whet...
متن کاملC1 posterior arch screw as an auxiliary anchor in posterior reconstruction for atlantoaxial dislocation associated with type II odontoid fracture: a case report and review of the literature
INTRODUCTION Although pedicle or lateral mass screws are usually chosen to fix atlantoaxial (C1-C2) instability, there is an increased risk for vertebral artery (VA) injury when used in patients with bone or arterial anomalies or osteoporotic bone. Here we report the C1 posterior arch screw as a new technique for upper cervical fixation. CASE DESCRIPTION A 90-year-old man complained of upper ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 38 2 شماره
صفحات -
تاریخ انتشار 2015