What is the most reliable ultrasound parameter for assessment of fetal head descent?

نویسندگان

  • F S Molina
  • R Terra
  • M P Carrillo
  • A Puertas
  • K H Nicolaides
چکیده

OBJECTIVES The aims of this study were, first, to establish the agreement between digital and ultrasound assessment of occipital position and, second, to evaluate the repeatability of the measurements of head direction, angle of the middle line, progression distance and angle of progression in women in the second stage of labor. METHODS Digital examination and then transabdominal ultrasound examination was performed on 50 women in the second stage of labor to determine the fetal occipital position. We also obtained three-dimensional (3D) blocks of the fetal head by transperineal sonography, and two experts in 3D ultrasound measured head direction, angle of the middle line, progression distance and angle of progression. Intraclass correlation coefficients with 95% CIs, and Bland-Altman analysis, were used to evaluate intraobserver and interobserver repeatability of measurements. RESULTS The fetal head position, determined by ultrasound examination, was occiput anterior in 33 (66%) cases and occiput lateral in 17 (34%) cases. Vaginal digital examination failed to identify the correct fetal head position by more than 45° in 33 (66%) cases. All four 3D ultrasound measurements were reproducible but the progression angle had the highest intraclass correlation coefficient for the same observer (0.94; 95% CI, 0.90-0.97) and for two different operators (0.84; 95% CI, 0.73-0.91). The progression angle was also the measurement for which smaller limits of agreement (LOA) were found in the Bland-Altman test, performed to calculate the intraobserver (bias 0.9; LOA, - 9.2 to 11.1%) and interobserver (bias 1.5; LOA, - 15.4 to 18.3%) variability. CONCLUSIONS Digital pelvic examination for determining the fetal head position during labor is not accurate. The most reproducible of the 3D measurements for progression of the fetal head in labor is the progression angle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasonographic fetal scapular length measurement for assessment of gestational age

one of the major goals of antenatal care is estimation of gestational age.the most widely used parameters for evaluation of fetal growth are biparietal diameter (BPD),femoral length (FL) and adbominal circumference (AC).to determine the value of prenatal ultrasonographic scapula measurements for fetal growth and gesattional age a prospective ultrasonographic cross-sectional study was conducted ...

متن کامل

A Free Line Search Steepest Descent Method for Solving Unconstrained Optimization Problems

In this paper, we solve unconstrained optimization problem using a free line search steepest descent method. First, we propose a double parameter scaled quasi Newton formula for calculating an approximation of the Hessian matrix. The approximation obtained from this formula is a positive definite matrix that is satisfied in the standard secant relation. We also show that the largest eigen value...

متن کامل

Inm-1: Indication of First Trimester Sonongraphy

Improvement in ultrasound technology, including transvaginalsonography and higher frequency probes, has led to a better understanding of early pregnancy development. The first trimester ultrasound have been identified that can be used to reassure women that their pregnancy is progressing normally or abnormal them that their pregnancy will fail. The practicing radiologist and obstetrician must b...

متن کامل

Fetal Head Position during the First Stage of Labor: Comparison between Vaginal Examination and Transabdominal Ultrasound

Introduction. Recent evidence indicates that clinical examination, for determination of fetal head position, is subjective and inaccurate. Present study was aimed to compare transabdominal ultrasound for fetal head position with vaginal examination during first stage of labor. Material and Methods. This prospective study was performed at a tertiary center during a two-year period. Before or aft...

متن کامل

Estimation of fetal weight by ultrasonic examination.

PURPOSE This study was to evaluate the accuracy and clinical application of a new technique in the fetal weight estimation by ultrasound. METHODS The fetal biparietal diameter (BPD), head circumference (HC) and femur length (FL) were measured by ultrasound examination within one week before delivery. Two different fetal abdominal sectors were measured for the assessment of abdominal circumfer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2010