Noise caused by a finite extinction ratio of the light modulator in CW cavity ring-down spectroscopy

نویسنده

  • H. Huang
چکیده

A model is presented for the effect of a finite extinction ratio of the light modulator used in continuous wave cavity ring-down spectroscopy (CW-CRDS) experiments. We present a simple analytical expression for the minimum isolation required to prevent a significant increase in the fluctuations of the cavity decay rate, which determine the sensitivity of the method. We also present systematic measurements of the signal to noise in CW-CRDS as a function of the effective isolation of the light modulator, and excellent agreement with the model is found. PACS 07.07.Df · 42.25.Hz · 42.79.Gn

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CW cavity ring-down spectroscopy (CRDS) with a semiconductor optical amplifier as intensity modulator

We summarized both advantages and disadvantages of different light modulators used in cw-CRDS experiments. For the first time, we introduce the use of a semiconductor optical amplifier (SOA) as light modulator in cw-CRDS. A direct comparison of the sensitivity realized on the same instrument using an SOA as modulator with use of an acousto-optic modulator (AOM) has been made. It is found that t...

متن کامل

Boron Nitride Sputter Erosion Measurements by Cavity Ring-Down Spectroscopy

Sputter erosion is a critically important process in many electric propulsion (EP) devices from the point of view of both lifetime assessment and contamination effects. In many Hall thrusters erosion of boron nitride (BN) is of primary interest. In this contribution we introduce the use of cavity ring-down spectroscopy (CRDS) as a diagnostic for measurement of sputtered BN. The measurement appr...

متن کامل

Light Source Effects on Aerosol Photoacoustic Spectroscopy Measurements.

Photoacoustic spectroscopy measurements of flame-generated soot aerosol coated with small amounts of water yielded absorption enhancements that were dependent on the laser used: quasi-continuous wave (Q-CW, ≈ 650 ps pulse duration and 78 MHz repetition rate) versus continuous wave (CW). Water coating thickness was controlled by exposing the aerosol to a set relative humidity (RH). At ≈ 85 % RH,...

متن کامل

Noise in cavity ring-down spectroscopy caused by transverse mode coupling.

In our continuous wave cavity ring-down spectroscopy (CW-CRDS) experiments, we have often observed that the decay time constant drops to a lower value at some cavity lengths or some intercavity pressures. The resulting instabilities lead to a reduction in the sensitivity of our CRDS system. We have deduced that the cause of this noise is the coupling between the TEM(00) mode that the laser exci...

متن کامل

Novel detection of aerosols: combined cavity ring-down and fluorescence spectroscopy.

High fluences inside cavity ring-down spectroscopy optical resonators lend themselves to fluorescence or Raman spectroscopy. An instrument at 488 nm was developed to measure extinction, and fluorescence of aerosols. A detection limit of 6 x 10;-9 cm;-1Hz;-1/2 (0.6 Mm;-1Hz;-1/2) was achieved. The fluorescence spectral power collected from a single fluorescent microsphere was 10 to 20 pW/nm. This...

متن کامل