Precision frequency measurements with interferometric weak values

نویسندگان

  • David J. Starling
  • P. Ben Dixon
  • Andrew N. Jordan
  • John C. Howell
چکیده

We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 ± 7 kHz/√Hz with only 2 mW of continuous-wave, single-mode input power. We describe the measurement of a weak value and show how even higher-frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Weak-values technique for velocity measurements.

In a recent Letter, Brunner and Simon proposed an interferometric scheme using imaginary weak values with a frequency-domain analysis to outperform standard interferometry in longitudinal phase shifts [Phys. Rev. Lett105, 010405 (2010)]. Here we demonstrate an interferometric scheme combined with a time-domain analysis to measure longitudinal velocities. The technique employs the near-destructi...

متن کامل

Interferometric weak value deflections: Quantum and classical treatments

Weak values [1] have presented or inspired intriguing possibilities for precision measurement. A recent example is by Hosten and Kwiat [2], where they were able to amplify the deflections arising from the spin Hall effect of light. The light fields used in their experiment, as well as in Ref. [3], were coherent quasiclassical fields and no apparent quantum mechanical system was employed in eith...

متن کامل

Power-Recycled Weak-Value-Based Metrology We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling

Power-Recycled Weak-Value-Based Metrology Report Title We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in all the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-tonoise ratio of the deflecti...

متن کامل

Shape Reconstruction and Weak Lensing Measurement with Interferometers: a Shapelet Approach

We present a new approach for image reconstruction and weak lensing measurements with interferometers. Based on the shapelet formalism presented in Refregier (2001), object images are decomposed into orthonormal Hermite basis functions. The shapelet coefficients of a collection of sources are simultaneously fit on the uv plane, the Fourier transform of the sky brightness distribution observed b...

متن کامل

Corrections for Wavelength Variations in Precision Interferometric Displacement Measurements

Precision interferometric displacement measurements require deadpath corrections to account for variations in wavelength during the course of the measurement. This paper discusses common errors in applying deadpath corrections and describes the correction necessary to fully account for variations in wavelength.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010