Micro-CT examination of human bone: from biopsies towards the entire organ.
نویسندگان
چکیده
Micro-CT systems are available that facilitate ex vivo examinations of human specimens as big as entire vertebrae, with spatial resolutions in the 10-micrometer range. This opens a new way for looking at entire bones in 3D. Accurate description of the internal microarchitecture of the entire organ can be obtained, at spatial resolutions previously achievable only on excised biopsies. These high resolution scans produce large datasets and come with costs and benefits, which have to be considered in the successful planning of an experiment. The aim of this paper is to present examples of human vertebrae scanned at high resolution (17 µm/pixel), allowing the visualization and quantification of the microarchitecture, and to discuss some aspects of using high resolution scans of such large specimens. The datasets were down-sampled to 34 µm and 68 µm pixel size, and their morphometric parameters compared to those obtained at 17 µm pixel size, in relation to data size and calculation time.
منابع مشابه
Beware of Bone Marrow: Incidental Detection and Primary Diagnosis of Solid Tumours in Bone Marrow Aspiration and Biopsies; A Study of 22 Cases
Background & objective: Introduction: First detection of any solid tumour as metastatic deposits in bone marrow directs clinicians to start searching for the primary tumour. Detection of bone marrow metastasis determines the stage of the malignancy, prognosis, mode of treatment, chemotherapeutic response and follow-up in case of relapse. The aim of the current...
متن کاملMeasurement of organ dose in chest CT examination using Monte Carlo simulation
Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...
متن کاملTissue Specific Expression of Human Calcitonin Gene in Potato Tubers by an Organ Specific Promoter
To increase the production level of heterologous proteins in plants, strategies such as choice of strongerpromoters, optimization of codon usage and specific localization of foreign proteins are of major concern.Calcitonin (CT), a 32 amino acid polypeptide is a powerful and specific inhibitor of bone resorption and isused to treat several human diseases. Calcitonin activity is...
متن کاملThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملStereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies.
Stereology applied on histological sections is the 'gold standard' for obtaining quantitative information on cancellous bone structure. Recent advances in micro computed tomography (microCT) have made it possible to acquire three-dimensional (3D) data non-destructively. However, before the 3D methods can be used as a substitute for the current 'gold standard' they have to be verified against th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 48 1 شماره
صفحات -
تاریخ انتشار 2012