Dose rate does matter in endovascular brachytherapy.
نویسندگان
چکیده
Dear Editor-in-Chief, In a recent letter, Das and Peters [1] have made the suggestion that dose rate is not an important factor in determining the effectiveness of endovascular brachytherapy. As we [2–4] and others [5] have argued earlier, we suggest here that the dose rate or, equivalently, the treatment time, is important. Das and Peters [1] correctly argue that if the irradiation time is much shorter than characteristic time for repair of ‘‘sublethal’’ damage, the dose rate will not matter, because there will be very little repair taking place during the treatment. The corollary, of course, is that if the irradiation time is not smaller than the characteristic repair time, dose rate will matter, with longer irradiation times resulting in reduced biological effects, because of sublethal damage repair during the irradiation. However, the implications of this argument depend on the actual value of the appropriate damage repair halftime. In their calculations, Das and Peters [1] used a repair halftime of 90 min, which is long compared with typical endovascular brachytherapy irradiation times, both for Sr/Y sources (irradiation time typically < 5 min), and also for Ir sources (irradiation time typically 20–35 min). Ergo, no dose-rate effects. However, the 90-min repair halftime that Das and Peters [1] uses is unrealistically long. Indeed, back in 1984, it was Peters et al. [6] who first provided quantitative data showing that repair halftimes for acutely responding normal tissues in vivo were less than 1 h, reporting measured values ranging from 18 to 54 min. This was in contrast to possibly longer times in late-responding vascular tissue, where values of the order of 90 min may indeed be appropriate [6]. Das and Peters [1] have applied here parameters relevant to late-occurring vascular damage. However, this is not pertinent to the endpoint of relevance here, which is radiation-induced reduction or prevention of restenosis— an acute response. The animal results suggesting that repair halftimes for acutely responding normal tissues are < 1 h [6] have since been corroborated by in vitro data from cells of human origin. An analysis [7] of in vitro dose-rate studies in 36 cell lines of human origin (mean repair halftime 32 min) includes a subanalysis of 6 cell lines derived from normal human tissues (mean repair halftime 22 min). Later studies with human aortic smooth muscle cells (repair halftime 30 min [4]) and porcine smooth muscle cells [5] also support the conclusion that an appropriate repair halftime here is about 30, not 90 min. A repair halftime of 30 min is still much longer than typical Sr/Y beta irradiation times, so dose rate would not be important there, but 30 min is comparable to typical irradiation times with Ir gamma rays. For example, the recent SCRIPPS trial [8] used an exposure time of about 35 min. In this case, the decrease in the effective dose (compared to that for a very short exposure) as estimated using the (as we argue) unrealistic parameters of Das and Peters (T1/2 = 90 min, a/b = 3 Gy [1]) is 7%—small enough, perhaps, to argue that dose rate is not so important. However, using parameters more appropriate for early-responding damage (T1/2 = 30 min, a/b = 8 Gy), this reduction in effective dose is 16%, no longer such a small correction. Of course all that needs to be done is to appropriately increase the dose to take into account the decreased effect with increasing treatment time—but this should be done when treatment times are greater than about 10 min.
منابع مشابه
Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty
Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...
متن کاملA Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular radiation medicine
دوره 2 4 شماره
صفحات -
تاریخ انتشار 2001