Trajectory of instantaneous axis of rotation in fixed lumbar spine with instrumentation

نویسندگان

  • Masataka Inoue
  • Tetsutaro Mizuno
  • Toshihiko Sakakibara
  • Takaya Kato
  • Takamasa Yoshikawa
  • Tadashi Inaba
  • Yuichi Kasai
چکیده

BACKGROUND Several studies showed instantaneous axis of rotation (IAR) in the intact spine. However, there has been no report on the trajectory of the IAR of a damaged spine or that of a fixed spine with instrumentation. It is the aim of this study to investigate the trajectory of the IAR of the lumbar spine using the vertebra of deer. METHODS Functional spinal units (L5-6) from five deer were evaluated with six-axis material testing machine. As specimen models, we prepared a normal model, a damaged model, and a pedicle screw (PS) model. We measured the IAR during bending in the coronal and sagittal planes and axial rotation. In the bending test, four directions were measured: anterior, posterior, right, and left. In the rotation test, two directions were measured: right and left. RESULTS The IAR of the normal model during bending moved in the bending direction. The IAR of the damaged model during bending moved in the bending direction, but the magnitude of displacement was bigger compared to that of the normal model. In the PS model, the IAR during bending test hardly moved. During rotation test, the IAR of the normal model and PS model located in the spinal canal, but the IAR of the damaged model located in the posterior part of the vertebral body. CONCLUSIONS In this study, the IAR of damaged model was scattering and that of PS model was concentrating. This suggests that higher mechanical load applied to the dura tube and nerve roots in the damaged model and less mechanical load applied to that in the PS model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanics of a Posterior Lumbar Motion Stabilizing Device: In Vitro Comparison to Intact and Fused Conditions.

STUDY DESIGN Nondestructive flexibility tests were performed in vitro, comparing multiple conditions of fixation in a single group of specimens. OBJECTIVE To compare the biomechanical behavior of the lumbar spine in the intact condition, after implanting a novel motion stabilizer, and after implanting a rigid fixator. SUMMARY OF BACKGROUND DATA Two specific scenarios that may benefit from d...

متن کامل

Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density.

We performed a biomechanical study on human cadaver spines to determine the effect of three different interbody cage designs, with and without posterior instrumentation, on the three-dimensional flexibility of the spine. Six lumbar functional spinal units for each cage type were subjected to multidirectional flexibility testing in four different configurations: intact, with interbody cages from...

متن کامل

Applied Inverse Methods for Optimal Deformation of Lumbar Artificial Disk/Implants with Numerical Reuleaux Method and 3D Voxelization-Computational Simulations

Lumbar artificial implants/disks experiment material deformations during the biomechanical loads/movements that are acting dynamically on the lumbar spine, e.g., flexion, extension, lateral flexion and torsion. During this biomechanical process disks and vertebras, (each spine part as a whole in general) move around an Instantaneous Rotation Center (IRC, 3D) or an Instantaneous Axis of Rotation...

متن کامل

Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review

STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "...

متن کامل

Frequency of Instrumentation in Lumbar Spinal Stenosis and Lumbar Disc Herniation

Background & Aim: Lumbosacral pain is extremely common as age increases. Spinal instrumentation is sometimes recommended for lumbar canal stenosis and disk herniation surgery. This study aimed at studying the frequency of instrumentation in patients referring to our center. Methods & Materials/Patients: This retrospective cross-sectional study included 1200 patients with low back and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017