Comparison of different biomaterials for glaucoma drainage devices: part 2.

نویسندگان

  • R S Ayyala
  • B Michelini-Norris
  • A Flores
  • E Haller
  • C E Margo
چکیده

BACKGROUND Inflammation associated with biomaterials may contribute to the failure of glaucoma drainage devices. OBJECTIVE To compare the inflammatory reaction associated with the insertion of Krupin silicone, Molteno polypropylene, and Acrosof end plates in the subconjunctival space of rabbits. METHODS Similar-sized glaucoma end plates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand rabbits were randomly assigned to the 3 groups. Conjunctival vascular hyperemia was graded in a masked fashion among the 3 groups. At the end of 3 weeks, the enucleated eyes were examined histologically and by scanning electron microscopy. RESULTS Molteno polypropylene was associated with more inflammation both in clinical observations and based on histological grading. Silicone and Acrosof were associated with less intense inflammation. One polypropylene end plate was extruded on day 21. CONCLUSIONS Polypropylene appears to be more inflammatory than silicone. Flexible biomaterials appear to be less inflammatory than rigid ones. CLINICAL RELEVANCE Bleb failure following glaucoma drainage device implantation could be related to the biomaterial-associated inflammation. Choosing a biomaterial with the least inflammatory potential might enhance the success rate of the glaucoma drainage device. Arch Ophthalmol. 2000;118:1081-1084

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different biomaterials for glaucoma drainage devices.

OBJECTIVES To compare the inflammatory reaction associated with the insertion of silicone and polypropylene endplates and endplates made of a new biocompatible polymer, Vivathane, in the rabbit subconjunctival space. METHODS Similar-sized endplates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand...

متن کامل

Glaucoma drainage devices; past, present, and future.

Glaucoma filtration surgery (GFS) has been shown to be more eVective at preventing disease progression than other primary treatment modalities in open angle glaucoma. 2 If it were possible to avoid complications associated with poor flow control, primary GFS would probably be offered more widely. Trabeculectomy, the procedure of choice in conventional GFS, has remained essentially unchanged for...

متن کامل

Comparison of the Effect of Hydrophilicity on Biocompatibility and Platelet Adhesion of Two Different Kinds of Biomaterials

      Determination of blood compatibility is an important problem in blood contacting devices. In this study, two classes of materials including polyurethane (based on polyethylene glycol and poly tetrametylene oxide) and polyvinyl alcohol samples, with different hydrophilicity properties were synthesized and their physico-chemical properties were compared. Water uptake ratio, FTIR spectroscop...

متن کامل

[Anterior segment optical coherence tomography in glaucoma].

In recent years, the rapid development of diagnostic optic devices has generated optical coherence tomography (OCT) as a new, non-invasive diagnostic method. With technical progress of the infrared spectrum at 1,310 nm, OCT of the anterior segment also became feasible. With anterior segment OCT different examinations which so far were ruled out by ultrasound in contact manner could be executed ...

متن کامل

Comparison of Six Different Silicones In Vitro for Application as Glaucoma Drainage Device

Silicones are widely used in medical applications. In ophthalmology, glaucoma drainage devices are utilized if conservative therapies are not applicable or have failed. Long-term success of these devices is limited by failure to control intraocular pressure due to fibrous encapsulation. Therefore, different medical approved silicones were tested in vitro for cell adhesion, cell proliferation an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 118 8  شماره 

صفحات  -

تاریخ انتشار 2000