Control Strategies for the DAB Based PV Interface System
نویسندگان
چکیده
This paper presents an interface system based on the Dual Active Bridge (DAB) converter for Photovoltaic (PV) arrays. Two control strategies are proposed for the DAB converter to harvest the maximum power from the PV array. The first strategy is based on a simple PI controller to regulate the terminal PV voltage through the phase shift angle of the DAB converter. The Perturb and Observe (P&O) Maximum Power Point Tracking (MPPT) technique is utilized to set the reference of the PV terminal voltage. The second strategy presented in this paper employs the Artificial Neural Network (ANN) to directly set the phase shift angle of the DAB converter that results in harvesting maximum power. This feed-forward strategy overcomes the stability issues of the feedback strategy. The proposed PV interface systems are modeled and simulated using MATLAB/SIMULINK and the EMTDC/PSCAD software packages. The simulation results reveal accurate and fast response of the proposed systems. The dynamic performance of the proposed feed-forward strategy outdoes that of the feedback strategy in terms of accuracy and response time. Moreover, an experimental prototype is built to test and validate the proposed PV interface system.
منابع مشابه
Optimized Operation of Current-Fed Dual Active Bridge DC-DC Converter for PV Applications
The current-fed dual active bridge (CF-DAB) dc–dc converter gains growing applications in photovoltaic (PV) and energy storage systems due to its advantages, e.g., a wide input voltage range, a high step-up ratio, a low input current ripple, and a multiport interface capability. In addition, the direct input current controllability and extra control freedom of the CF-DAB converter make it possi...
متن کاملAn LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems
Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...
متن کاملPower Balancing Control for Grid Energy Storage System in PV Applications—Real Time Digital Simulation Implementation
Grid energy storage system for PV Applications is connected with three different power sources i.e. PV Array, Battery and the Grid. It is advisable to have Isolation between these three different sources to provide safety for the equipment. The configuration proposed in this paper provides the complete isolation between the three sources. A Power Balancing Control (PBC) for this configuration i...
متن کاملA New Non-linear Control of the Four-Leg Inverter with Decoupled Model and Fast Dynamic Response for PV Generation Systems
Distributed generation (DG) will play an important role in future power generation systems, especially in stand-alone applications. Three phase four-leg inverter is a well-known topology which can be used as an interface power converter for DGs. Thanks to the fourth leg to provide the neutral path, the four-leg inverter is able to supply balanced loads as well as unbalanced loads. In this paper...
متن کاملPower Balancing Control for Grid Energy Storage System in Photovoltaic Applications—Real Time Digital Simulation Implementation
A grid energy storage system for photo voltaic (PV) applications contains three different power sources i.e., PV array, battery storage system and the grid. It is advisable to isolate these three different sources to ensure the equipment safety. The configuration proposed in this paper provides complete isolation between the three sources. A Power Balancing Control (PBC) method for this configu...
متن کامل