Tremor suppression in ECG

نویسندگان

  • Ivan A Dotsinsky
  • Georgy S Mihov
چکیده

BACKGROUND Electrocardiogram recordings are very often contaminated by high-frequency noise usually power-line interference and EMG disturbances (tremor). Specific method for interference cancellation without affecting the proper ECG components, called subtraction procedure, was developed some two decades ago. Filtering out the tremor remains a priori partially successful since it has a relatively wide spectrum, which overlaps the useful ECG frequency band. METHOD The proposed method for tremor suppression implements the following three procedures. Contaminated ECG signals are subjected to moving averaging (comb filter with linear phase characteristic) with first zero set at 50 Hz to suppress tremor and PL interference simultaneously. The reduced peaks of QRS complexes and other relatively high and steep ECG waves are then restored by an introduced by us procedure called linearly-angular, so that the useful high frequency components are preserved in the range specified by the embedded in the ECG instrument filter, usually up to 125 Hz. Finally, a Savitzky-Golay smoothing filter is applied for supplementary tremor suppression outside the QRS complexes. RESULTS The results obtained show a low level of the residual EMG disturbances together with negligible distortion of the wave shapes regardless of rhythm and morphology changes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple Approach for Tremor Suppression in Electrocardiograms

Abstract: Electrocardiogram recordings are very often contaminated by high-frequency noise usually power-line interference and EMG disturbances (tremor). Filtering out the tremor remains a priori partially successful since it has a relatively wide spectrum, which overlaps the useful ECG frequency band by aperiodic noise. The proposed simple approach for tremor suppression uses heuristic relatio...

متن کامل

BioMedical Engineering OnLine Research Tremor suppression in ECG

Background: Electrocardiogram recordings are very often contaminated by high-frequency noise usually power-line interference and EMG disturbances (tremor). Specific method for interference cancellation without affecting the proper ECG components, called subtraction procedure, was developed some two decades ago. Filtering out the tremor remains a priori partially successful since it has a relati...

متن کامل

Optimal design of a vibration absorber for tremor control of arm in Parkinson's disease

Because the underlying physiology of pathological tremor in a Parkinson's patient is not well understood, the existing physical and drug therapies have not been successful in tremor treatment. Different mathematical modeling of such vibration has been introduced to investigate the problem and reduce the existing vibration. Most of the models have represented the induced vibration as a sinusoida...

متن کامل

Power-line interference elimination from ECG: dynamic evaluation of the linearity criterion

Introduction Subtraction procedure for power-line elimination has been elaborated two decades ago and continuously improved during the years. It is extremely efficient with changing amplitude and frequency of the interference. The performance is slightly reduced in case of continuous wellexpressed tremor. Dynamic estimation of the linearity criterion (M) elaborated in 2000 proved to solve the p...

متن کامل

Global pseudo-atrial flutter ECG appearance secondary to unilateral parkinsonian tremor.

To cite: Nam MCY, Best L, Greaves K, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2015214048 DESCRIPTION An 82-year-old man with previous bioprosthetic aortic valve replacement for aortic stenosis had a routine ECG (figure 1). This was thought to represent an atrial tachycardia with cycle length 280 ms and 3:1 atrioventricular response. A diagnosis of at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2008