A computational model-based validation of Guyton's analysis of cardiac output and venous return curves.
نویسندگان
چکیده
Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.
منابع مشابه
Understanding Guyton's venous return curves.
Based on observations that as cardiac output (as determined by an artificial pump) was experimentally increased the right atrial pressure decreased, Arthur Guyton and coworkers proposed an interpretation that right atrial pressure represents a back pressure restricting venous return (equal to cardiac output in steady state). The idea that right atrial pressure is a back pressure limiting cardia...
متن کاملClinical review: Guyton - the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output
Arthur Guyton's concepts of the determinative role of right heart filling in cardiac output continue to be controversial. This paper reviews his seminal experiments in detail and clarifies the often confusing concepts underpinning his model. One primary criticism of Guyton's model is that the parameters describing venous return had not been measured in a functioning cardiovascular system in hum...
متن کاملImportance of atrial compliance in cardiac performance.
Effects of changes in atrial compliance on cardiac performance were analyzed using a circulatory analog model. The atrium was assumed to be a noncontracting chamber with a constant compliance. It connected the venous return system, which was represented by mean circulatory filling pressure and a venous return resistance in accordance with Guyton's concept, with the ventricle, which was characte...
متن کاملA closed circulatory system model.
The model to be described is a “closed” system, comprised of four principal components : a pump, an arterial capacitance, a peripheral resistance, and a venous capacitance. The pump is servo-controlled, such that “cardiac output” is a function of venous pressure (FrankStarling mechanism). Also, because the model is a closed system, the venous pressure is a function of the cardiac output. The mo...
متن کاملBench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computers in cardiology
دوره 29 شماره
صفحات -
تاریخ انتشار 2002