Width-Controlling Fixation of Symphyseal/Parasymphyseal Fractures Associated With Bilateral Condylar Fractures With 2 2.0-mm Miniplates: A Retrospective Investigation of 45 Cases.

نویسندگان

  • Shuo Chen
  • Yi Zhang
  • Jin-Gang An
  • Yang He
چکیده

PURPOSE Symphyseal and parasymphyseal fractures and bilateral condylar fractures represent a pattern that is quite challenging to manage. This study evaluated the treatment outcomes of a group of patients who underwent surgery using miniplate fixation for anterior mandibular fractures. MATERIALS AND METHODS This retrospective case series study reviewed patients with bilateral condylar fractures and noncomminuted symphyseal and parasymphyseal fractures. The patients were surgically treated from 2008 to 2014 in the department of oral surgery. Evaluation of facial width control was considered the primary outcome variable, which consisted of clinical assessment and measurement of the lingual gap using computed tomography. Medical information was collected before surgery. Temporomandibular joint function and postoperative complications also were evaluated during follow-up. A paired sample t test was used for statistical analysis. RESULTS Forty-five patients (37 male, 8 female; mean age, 34.8 ± 14.5 yr; range, 16 to 74 yr) were included in this study. Lingual gaps measured before surgery (3.38 ± 0.61 mm) and after surgery (0.64 ± 0.14 mm) were significantly different (P < .001). No patient was rated as "unsatisfactory" after esthetic evaluation of facial width. CONCLUSION For noncomminuted symphyseal and parasymphyseal fractures associated with bilateral condylar fractures, 2 2.0-mm miniplates with monocortical screws are stable and efficacious in controlling mandibular width when bilateral condylar fractures are anatomically reduced and stably fixated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Miniplate fixation of fractures of the symphyseal and parasymphyseal regions of the mandible: a review of 218 patients.

OBJECTIVE To review our experience with miniplate fixation of fractures of the symphyseal and parasymphyseal regions of the mandible. METHODS A retrospective review of all mandible fractures treated from July 1, 1999, through July 31, 2011, by one of us (Y.D.) was performed. Intraoral, open rigid fixation of noncomminuted symphyseal and parasymphyseal fractures was performed using a combinati...

متن کامل

Correlation between Condylar Fracture Pattern after Parasymphyseal Impact and Condyle Morphological Features: A Retrospective Analysis of 107 Chinese Patients

BACKGROUND The treatment of the condylar fractures is difficult. Factors that result in the fractures are complex. The objective of this morphometric study was to investigate the relationship between condylar fracture patterns and condylar morphological characteristics. METHODS We conducted a retrospective analysis of 107 patients admitted to the West China Hospital of Stomatology for bilater...

متن کامل

A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation

AIMS AND OBJECTIVES To compare the maximum voluntary bite force generated at different periods during mandibular fracture healing using miniplates and microplates as means of rigid internal fixation. MATERIALS AND METHODS Maximum voluntary bite force was recorded in healthy young individuals of different age group from either gender. Patients suffering from symphyseal and parasymphyseal and b...

متن کامل

Clinical evaluation of 3 types of plate osteosynthesis for fixation of condylar neck fractures.

PURPOSE The goal of this study was to evaluate outcomes in patients who had condylar neck fractures treated with 3 different plating techniques. PATIENTS AND METHODS A retrospective study was performed on 37 patients with 40 fractures of the condylar neck that were reduced and stabilized using an approach involving exposure of the facial nerve. Stabilization was achieved with a single minipla...

متن کامل

Assessment of 1.5 Mm Low Profile Titanium Miniplate As a Tension Band in Treatment of Mandibular Parasymphyseal Fractures

Purpose: The study was carried out to assess the use of 1.5 mm low profile titanium miniplate as a tension band in the treatment of mandibular parasymphyseal fractures. Patients and Methods: The study was performed on 12 patients; 10 males and 2 females suffering from mandibular parasymphyseal fractures with/without other fractures in the maxillofacial region. Patients were selected from those ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 2016