High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: comparison of surface coil and volume coil.
نویسندگان
چکیده
PURPOSE To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). MATERIALS AND METHODS MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3 T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees , 1 mm slice-thickness, 60 mm field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees , 0.8 mm slice-thickness, 80 mm FOV, 256 x 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. RESULTS SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. CONCLUSION SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
منابع مشابه
High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
This study is intended as a review of 3Tesla (T) magnetic resonance (MR) imaging of the triangular fibrocartilage complex (TFCC). The recent advances in MR imaging, which includes high field strength magnets, multi-channel coils, and isotropic 3-dimensional (3D) sequences have enabled the visualization of precise TFCC anatomy with high spatial and contrast resolution. In addition to the routine...
متن کاملThe Study of Ulnar Variance with High-Resolution MRI: Correlation with Triangular Fibrocartialge Complex and Cartilage of Ulnar Side of the Wrist
INTRODUCTION Ulnar variance affects the force distribution across the wrist and is related with some ulnar pathologies. Ulnar minus variance is associated with Kienböck’s disease, whereas ulnar plus variance plays an important role in triangular fibrocartilage complex (TFCC) tear and ulnar impaction syndrome. Ulnar variance is measured based on plain radiograph. However, plain radiograph shows ...
متن کاملWrist Imaging: Ligaments and Triangular Fibrocartilage
Magnetic resonance imaging (MRI) and MR arthrography are both effective means to evaluate the instrinsic and extrinsic ligaments of the wrist, as well as the triangular fibrocartilage (TFC) [1-6]. High resolution detail of the wrist can be achieved with a variety of magnet strengths, with 1.5 Tesla (T) and 3T being the most commonly utilized in current practice. Dedicated wrist coils are critic...
متن کاملHigh-resolution 3T Magnetic Resonance Imaging of the Triangular Fibrocartilage Complex in Chinese Wrists: Correlation with Cross-sectional Anatomy
BACKGROUND The injury of the triangular fibrocartilage complex (TFCC) is a common cause of ulnar-sided wrist pain. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) could demonstrate the detailed complex anatomy of TFCC in Chinese. METHODS Fourteen Chinese cadaveric wrists (from four men and three women; age range at death from 30 to 60 years;...
متن کاملCan the Diagnostics of Triangular Fibrocartilage Complex Lesions Be Improved by MRI-Based Soft-Tissue Reconstruction? An Imaging-Based Workup and Case Presentation
Introduction. The triangular fibrocartilage complex (TFCC) provides both mobility and stability of the radiocarpal joint. TFCC lesions are difficult to diagnose due to the complex anatomy. The standard treatment for TFCC lesions is arthroscopy, posing surgery-related risks onto the patients. This feasibility study aimed at developing a workup for soft-tissue reconstruction using clinical imagin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2007