CONTINUING EDUCATION Radiation Safety Review for 511-keV Emitters in Nuclear Medicine
نویسنده
چکیده
With the advent of high-energy collimators and dual-head coincidence cameras, standard nuclear medicine facilities will soon begin imaging with PET isotopes. The use of 511keV emitters raises new radiation safety concerns for technologists traditionally limited to handling mTc and other low-energy isotopes. This article is a basic review of positron emitters, measurement concerns, exposure rates, shielding requirements and external radiation exposure mitigation. Newly developed PET shielding products are presented and regulatory status is discussed briefly.
منابع مشابه
Radiation safety review for 511-keV emitters in nuclear medicine.
With the advent of high-energy collimators and dual-head coincidence cameras, standard nuclear medicine facilities will soon begin imaging with PET isotopes. The use of 511-keV emitters raises new radiation safety concerns for technologists traditionally limited to handling 99mTc and other low-energy isotopes. This article is a basic review of positron emitters, measurement concerns, exposure r...
متن کاملRadiation dose to PET technologists and strategies to lower occupational exposure.
OBJECTIVE The use of PET in Australia has grown rapidly. We conducted a prospective study of the radiation exposure of technologists working in PET and evaluated the occupational radiation dose after implementation of strategies to lower exposure. METHODS Radiation doses measured by thermoluminescent dosimeters over a 2-y period were reviewed both for technologists working in PET and for tech...
متن کاملCharacterization of the energy response and backscatter contribution for two electronic personal dosimeter models
We characterized the energy response of personal dose equivalent (Hp(10) in mrem) and the contribution of backscatter to the readings of two electronic personal dosimeter (EPD) models with radionuclides commonly used in a nuclear medicine clinic. The EPD models characterized were the RADOS RAD-60R, and the SAIC PD-10i. The experimental setup and calculation of EPD energy response was based on A...
متن کامل511 keV photons from color superconducting dark matter.
We discuss the possibility that the recent detection of 511 keV gamma rays from the galactic bulge, as observed by the International Gamma-Ray Astrophysics Laboratory, can be naturally explained by the supermassive very dense droplets (strangelets) of dark matter. These droplets are assumed to be made of ordinary light quarks (or antiquarks) condensed in a nonhadronic color superconducting phas...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کامل