Noninvasive measurement of intrathoracic fluids.

نویسندگان

  • L E Baker
  • J C Denniston
چکیده

(A) BAND ELECTRODE ARRAY (B) CIRCUMFERENTIAL SPOT (C) LONGITUDINAL SPOT ELECTRODE ARRAY ELECTRODE ARRAY FIGUBE 1. Four terminal systems for the measurement of thoracic impedance. A. Flexible metal electrodes encircling neck and thorax. 50 kHz constant sinusoidal current (1 mA rms) was applied to electrodes 1, 4. Voltage changes reflecting thoracic impedance changes were picked up from electrodes 2, 3. B. Stainless steel “spot” electrodes (1 cm diameter) sutured to chest wall at level of sixth intercostal space. Twenty kllz constant sinusoidal current (1 mA rms) was applied to electrodes 2, 4, and impedance changes between other pairs of electrodes were recorded. C. Standard disposable ECG type electrodes were applied to thorax as shown. Twenty kHz constant sinusoidal current (1 mA rms) was applied to electrodes 1, 6, and impedance changes between electrodes 2, 3, or 4, 5 were recorded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Silent Tachypnoea in a Neonate: A Rare Presentation of Right Side Bochdalek Hernia with Intrathoracic Kidney

Congenital diaphragmatic hernia (CDH) is a rare condition. The reported incidence of intrathoracic renal ectopia due to CDH is also rare. A right-sided thoracic kidney is much less common due to the location of the liver. Isolated intrathoracic kidney is usually asymptomatic and diagnosed incidentally on chest imaging. The authors report on a 21days old female infant with late-presenting right ...

متن کامل

Ultrasonics evaluation of intrathoracic masses.

B mode ultrasound can be used to evaluate intrathoracic masses that contact the chest wall. It provides a noninvasive technique to distinguish cystic from solid lesions and to assess the internal structure. Four cases are reported in which this procedure was used to provide diagnositc information.

متن کامل

Determination of Thermo-physical Properties of Non-Newtonian Fluids Using a Coaxial Cylindrical Cell

In this study the thermal conductivity and the volumetric heat capacity of non-Newtonian fluids are investigated. These fluids find many applications in chemical, medical and food industries. They mostly have viscoelastic behavior and generally differ from Newtonian fluids. Two non-Newtonian fluids, solutions of xanthan and carboxy methyl cellulose in water with various concentrations have bee...

متن کامل

Design and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids

Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...

متن کامل

Intrathoracic Displacement of Fractured Right Humeral Head: A Case Report

Intrathoracic displacement of the humeral head is a very uncommon condition and can be life threatening due to lungor heart injuries. There is a report of this condition where intrathoracic bone fragment was missed. Because of rareincidence there is no guideline for approach and treatment of this condition.We hereby present a case of intrathoracic displacement of fractured hum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 65  شماره 

صفحات  -

تاریخ انتشار 1974