Noninvasive measurement of intrathoracic fluids.
نویسندگان
چکیده
(A) BAND ELECTRODE ARRAY (B) CIRCUMFERENTIAL SPOT (C) LONGITUDINAL SPOT ELECTRODE ARRAY ELECTRODE ARRAY FIGUBE 1. Four terminal systems for the measurement of thoracic impedance. A. Flexible metal electrodes encircling neck and thorax. 50 kHz constant sinusoidal current (1 mA rms) was applied to electrodes 1, 4. Voltage changes reflecting thoracic impedance changes were picked up from electrodes 2, 3. B. Stainless steel “spot” electrodes (1 cm diameter) sutured to chest wall at level of sixth intercostal space. Twenty kllz constant sinusoidal current (1 mA rms) was applied to electrodes 2, 4, and impedance changes between other pairs of electrodes were recorded. C. Standard disposable ECG type electrodes were applied to thorax as shown. Twenty kHz constant sinusoidal current (1 mA rms) was applied to electrodes 1, 6, and impedance changes between electrodes 2, 3, or 4, 5 were recorded.
منابع مشابه
Silent Tachypnoea in a Neonate: A Rare Presentation of Right Side Bochdalek Hernia with Intrathoracic Kidney
Congenital diaphragmatic hernia (CDH) is a rare condition. The reported incidence of intrathoracic renal ectopia due to CDH is also rare. A right-sided thoracic kidney is much less common due to the location of the liver. Isolated intrathoracic kidney is usually asymptomatic and diagnosed incidentally on chest imaging. The authors report on a 21days old female infant with late-presenting right ...
متن کاملUltrasonics evaluation of intrathoracic masses.
B mode ultrasound can be used to evaluate intrathoracic masses that contact the chest wall. It provides a noninvasive technique to distinguish cystic from solid lesions and to assess the internal structure. Four cases are reported in which this procedure was used to provide diagnositc information.
متن کاملDetermination of Thermo-physical Properties of Non-Newtonian Fluids Using a Coaxial Cylindrical Cell
In this study the thermal conductivity and the volumetric heat capacity of non-Newtonian fluids are investigated. These fluids find many applications in chemical, medical and food industries. They mostly have viscoelastic behavior and generally differ from Newtonian fluids. Two non-Newtonian fluids, solutions of xanthan and carboxy methyl cellulose in water with various concentrations have bee...
متن کاملDesign and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids
Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...
متن کاملIntrathoracic Displacement of Fractured Right Humeral Head: A Case Report
Intrathoracic displacement of the humeral head is a very uncommon condition and can be life threatening due to lungor heart injuries. There is a report of this condition where intrathoracic bone fragment was missed. Because of rareincidence there is no guideline for approach and treatment of this condition.We hereby present a case of intrathoracic displacement of fractured hum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 65 شماره
صفحات -
تاریخ انتشار 1974