Ventricular shunt tap as a predictor of proximal shunt malfunction in children: a prospective study.

نویسندگان

  • Brandon G Rocque
  • Samir Lapsiwala
  • Bermans J Iskandar
چکیده

OBJECT The clinical diagnosis of cerebrospinal fluid (CSF) shunt malfunction can be challenging. In this prospective study, the authors evaluated a common method of interrogating shunts: the shunt tap; specifically, its ability to predict proximal malfunction. METHODS The authors performed standardized shunt taps in a consecutive series of cases involving children with suspected or proven shunt malfunction, assessing flow and, when possible, opening pressure. Data were collected prospectively, and results analyzed in light of surgical findings. RESULTS A shunt tap was performed prior to 68 operative explorations in 51 patients. Of the 68 taps, 28 yielded poor or no CSF flow on aspiration. After 26 of these 28 procedures, proximal catheter obstruction was identified. After 28 taps with good CSF return and normal or low opening pressure, 18 shunts were found to have a proximal obstruction, 8 had no obstruction, and 2 had a distal obstruction. Another 12 taps with good CSF flow had high opening pressure; subsequent surgery showed distal obstruction in 11 of the shunts, and proximal obstruction in 1. The positive predictive value of poor flow was 93%, while good flow on shunt tap predicted adequate proximal catheter function in only 55% of cases. CONCLUSIONS Poor flow of CSF on shunt tap is highly predictive of obstruction of the proximal catheter. Because not all patients with good flow on shunt tap underwent surgical shunt exploration, the specificity of this test cannot be determined. Nonetheless, a shunt tap that reveals good flow with a normal opening pressure can be misleading, and management of such cases should be based on clinical judgment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of shunt malfunction using shunt site reservoir.

OBJECTIVE To determine the usefulness of a separate reservoir placed at the site of the shunt in evaluation of shunt malfunction. METHODS AND MATERIALS A ventricular catheter was placed alongside the proximal catheter of the shunt and connected to a subgaleal reservoir in 17 patients, in 9 a double-lumen catheter with integrated reservoir and in 13 patients a dual catheter with a double-port ...

متن کامل

Evaluation of ventriculoperitoneal shunt malfunction regarding ventricular catheter placement

AbstractBackgroundline of treatment for management of hydrocephalus despite available new techniques andsystems of shunting. Associated complications should be recognized and managed properly,but the most recognized complications are shunt obstruction which its prevalencethrough surgical approach is discussed here. Two approaches (frontal and parietal) are usedto insert ventriculoperitoneal shu...

متن کامل

Comparison of rapid cranial MRI to CT for ventricular shunt malfunction.

OBJECTIVES To compare the accuracy of rapid cranial magnetic resonance imaging (MRI) with that of computed tomography (CT) for diagnosing ventricular shunt malfunction. METHODS We performed a single-center, retrospective cohort study of children ≤21 years of age who underwent either rapid cranial MRI or cranial CT in the emergency department (ED) for evaluation of possible ventricular shunt m...

متن کامل

Comparison of 1-year outcomes for the Chhabra and Codman-Hakim Micro Precision shunt systems in Uganda: a prospective study in 195 children.

OBJECT The author investigated the 1-year outcomes for shunt treatment of hydrocephalic children in Uganda, comparing the results using the inexpensive Chhabra shunt ($35 US dollars), widely used in East Africa, with those using the Codman-Hakim Micro Precision Valve shunt ($650). METHODS The results in 195 consecutive children (mostly infants) in whom shunts were placed were studied prospect...

متن کامل

Pitfalls in the diagnosis of ventricular shunt dysfunction: radiology reports and ventricular size.

INTRODUCTION The diagnosis of shunt malfunction can be difficult even for the experienced clinician and may lead to disastrous circumstances when misinterpreted. Less experienced physicians may rely more on radiographic reports as a primary diagnostic modality. In this study, we evaluated the reliability of using these reports without accurate clinical assessment. METHODS All shunt revisions ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery. Pediatrics

دوره 1 6  شماره 

صفحات  -

تاریخ انتشار 2008