Generating method-specific Reference Ranges – A harmonious outcome?

نویسندگان

  • Graham R. Lee
  • Alison Griffin
  • Kieran Halton
  • Maria C. Fitzgibbon
چکیده

OBJECTIVES When laboratory Reference Ranges (RR) do not reflect analytical methodology, result interpretation can cause misclassification of patients and inappropriate management. This can be mitigated by determining and implementing method-specific RRs, which was the main objective of this study. DESIGN AND METHODS Serum was obtained from healthy volunteers (Male + Female, n > 120) attending hospital health-check sessions during June and July 2011. Pseudo-anonymised aliquots were stored (at - 70 °C) prior t° analysis on Abbott ARCHITECT c16000 chemistry and i2000SR immunoassay analysers. Data were stratified by gender where appropriate. Outliers were excluded statistically (Tukey method) to generate non-parametric RRs (2.5th + 97.5th percentiles). RRs were compared to those quoted by Abbott and UK Pathology Harmony (PH) where possible. For 7 selected tests, RRs were verified using a data mining approach. RESULTS For chemistry tests (n = 23), Upper or Lower Reference Limits (LRL or URL) were > 20% different from Abbott ranges in 25% of tests (11% from PH ranges) but in 38% for immunoassay tests (n = 13). RRs (mmol/L) for sodium (138-144), potassium (3.8-4.9) and chloride (102-110) were considerably narrower than PH ranges (133-146, 3.5-5.0 and 95-108, respectively). The gender difference for ferritin (M: 29-441, F: 8-193 ng/mL) was more pronounced than reported by Abbott (M: 22-275, F: 5-204 ng/mL). Verification studies showed good agreement for chemistry tests (mean [SD] difference = 0.4% [1.2%]) but less so for immunoassay tests (27% [29%]), particularly for TSH (LRL). CONCLUSION Where resource permits, we advocate using method-specific RRs in preference to other sources, particularly where method bias and lack of standardisation limits RR transferability and harmonisation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Age-Related Prostate Specific Antigen Reference Ranges in Healthy Northern Iranian Men

Background: Prostate cancer is the third most common malignancy in men worldwide. Despite being a helpful biomarker in prostate cancer, prostate specific antigen (PSA) is affected by different factors including age, lifestyle, geographical region and ethnicity. Objective: To determine the age specific serum PSA level among healthy Northern Iranian men and to compare the results of our study wit...

متن کامل

Differential Flatness Method Based on Pre-set Guidance and Control Subsystem Design for a Surface to Surface Flying Vehicle (TECHNICAL NOTE)

The purpose of this paper is to design a guidance and control system and evaluate the performance of a sample surface‑to‑surface flying object based on preset guidance with a new prospective. In this study, the main presented idea is usage of unique property of governor differential equations in order to design and develop a controlled system. Thereupon a set of system output variables have bee...

متن کامل

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

Trimester-Specific Reference Ranges for Free Thyroxine Hormone in Iranian Pregnant Women

Introduction: Physiological changes during pregnancy affect thyroid function and also free thyroxine (FT4) assay methods. These impacts make immunoassays unreliable for detecting hypothyroxinemia during pregnancy. Due to pregnant women’s adequate consumption of iodine in Iran, reference ranges of FT4 needs to be obtained for this group. Materials and Methods: A total of 1077 Iranian pregnant wo...

متن کامل

An Interactive Method for Generating Harmonious Color Schemes

We present an interactive visualization tool for generating color schemes that can be used by both professional artists and novice designers to improve their design efficiency. The method is developed on two color harmony principles of familial factors and rhythmic spans from conventional color theories. The interactive tool makes uses of these principles for users to interactively generate col...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017