Artefacts in cone beam CT

نویسندگان

  • Prashant P. Jaju
  • Mayuri Jain
  • Ajita Singh
  • Akanksha Gupta
  • Rishi Raj
چکیده

Cone beam computed tomography (CBCT) is the modern third dimension applied in the field of oral maxillofacial region. With lower radiation dose compared to conventional CT, its applications in dentistry has increased tremendously. Artefacts can seriously degrade the quality of computed tomographic (CBCT) images, sometimes to the point of making them diagnostically unusable. To optimize image quality, it is necessary to understand why artifacts occur and how they can be prevented or suppressed. CT artifacts originate from a range of sources; physical based, scanner based and patient based. This article highlights the causes of artefacts on CBCT images and methods to avoid them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artefacts in CBCT: a review.

Artefacts are common in today's cone beam CT (CBCT). They are induced by discrepancies between the mathematical modelling and the actual physical imaging process. Since artefacts may interfere with the diagnostic process performed on CBCT data sets, every user should be aware of their presence. This article aims to discuss the most prominent artefacts identified in the scientific literature and...

متن کامل

Exact and approximate algorithms for helical cone-beam CT.

This paper concerns image reconstruction for helical x-ray transmission tomography (CT) with multi-row detectors. We introduce two approximate cone-beam (CB) filtered-backprojection (FBP) algorithms of the Feldkamp type, obtained by extending to three dimensions (3D) two recently proposed exact FBP algorithms for 2D fan-beam reconstruction. The new algorithms are similar to the standard Feldkam...

متن کامل

A dual modality of cone beam CT and electrical impedance tomography for lung imaging

Electrical impedance tomography (EIT) is a new and emerging tomographic imaging system, which is able to provide high temporal resolution with low spatial resolution. In past few years, the EIT has been extensively studied for lung monitoring. Cone beam CT (CBCT) is an imaging system used in radiation therapy unit. The CBCT suffers from motion artefacts, making treatment planning inaccurate. Th...

متن کامل

Compensation of affine deformations in fan and cone beam projections

Aims Motion or deformation of an object during the CT acquisition will produce artefacts in the reconstructions such as streaking and blurring 1 . These artefacts are the result of inconsistent information in the different projections images. This work presents a technique to transform the projections, and their projection geometry, at different time points to projections consistent with one pa...

متن کامل

Cone Beam CT Evaluation of the Bony Changes in the Temporomandibular Joint and the Association with the Clinical Symptoms of Temporomandibular Joint Disorders

Introduction: Temporomandibular joint (TMJ) disorders are among the most prevalent abnormalities of the jaw, which affect the masticatory system, including the muscles, TMJ, and tendons. Clinical examination alone cannot determine the cause of temporomandibular disorder (TMD). In most cases, the cause of TMD and a proper treatment plan are determined based on imaging modalities. The present stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013