A new heart rate variability-based method for the estimation of oxygen consumption without individual laboratory calibration: application example on postal workers.

نویسندگان

  • Juhani Smolander
  • Tanja Juuti
  • Marja-Liisa Kinnunen
  • Kari Laine
  • Veikko Louhevaara
  • Kaisa Männikkö
  • Heikki Rusko
چکیده

Traditionally, the estimation of oxygen consumption (VO2) at work using heart rate (HR) has required the determination of individual HR/VO2 calibration curves in a separate exercise test in a laboratory (VO2-TRAD). Recently, a new neural network-, and heart rate variability-based method has been developed (Firstbeat PRO heartbeat analysis software) for the estimation of VO2 without individual calibration (VO2-HRV). In the present study, the VO2-values by the VO2-HRV were compared with the values by VO2-TRAD in 22 postal workers. Within individuals the correlation between the two methods was high (range 0.80-0.99). The VO2-TRAD gave higher values of VO2 compared to VO2-HRV (19%) especially during low physical activity work when non-metabolic factors may increase HR. When assessed in different HR categories, the smallest difference (11%), and highest correlations (range 0.83-0.99) in VO2 between the methods were observed at higher HR levels. The results indicate that the VO2-HRV is a potentially useful method to estimate VO2 in the field without laboratory calibration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Heart Rate Based Energy Expenditure Estimation Method at Glance

• The described energy expenditure (EE) estimation method is based on a well-known relationship between cardiorespiratory function and measured energy expenditure. • The accuracy of the described heart beat based EE-estimation method is substantially better than the accuracy of traditional heart rate level based estimation. • Increased accuracy is due to methods ability to utilize information o...

متن کامل

بررسی تغییرات درجه حرارت در میزان حداکثر اکسیژن مصرفی و زمان رسیدن به خستگی کارگران کارخانه ریسندگی

Background: Fatigue is an important inhibiting factor in human performance, so with rising aerobic power could be overcome individual fatigue. Based on the importance of maximum oxygen consumption at fatigue threshold, the purpose of this study was to evaluate changes in temperature of the maximum rate of oxygen consumption and time to exhaustion in workers of spinning factory. Methods: In thi...

متن کامل

I-11: The Use of Oxygen Consumption for Oocyte and Embryo Selection

Assisted human reproduction is characterized by a high variability in results regarding pregnancy and birth rates. In fact, in a cohort of fertilized oocytes from the same stimulation cycle, the development rate varies drastically, even though produced at the same time and under similar conditions. This variability results in large differences in implantation potential of human embryos develope...

متن کامل

Real Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation

Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...

متن کامل

A Predictive Model for Emotion Recognition Based on Individual Characteristics and Autonomic Changes

Introduction: The importance of individual differences in the problem of emotion recognition has been repeatedly stated in the studies. The major concentration of this study was the prediction of heart rate variability (HRV) changes due to affective stimuli from the subject characteristics. These features were age (A), gender (G), linguality (L), and sleep (S) information. In addition, the most...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied ergonomics

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2008