Automatic Outer Volume Suppression (OVS) Slice Placement for Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI)

نویسندگان

  • T. Li
  • M. Martinez-Ramon
  • G. Heileman
  • S. Posse
چکیده

T. Li, M. Martinez-Ramon, G. Heileman, S. Posse MIND Institute, Albuquerque, NM, United States, University of New Mexico, Albuquerque, nm, United States, MIND Imaging Center, Albuquerque, nm, United States Introduction: Outer volume suppression is used in MR spectroscopic imaging to reduce contamination from peripheral lipid signals. The placement of lipid suppression slices (sat bands) by a human operator is time-consuming and introduces variability. Placement of sat bands is particularly challenging for volumetric studies due to the irregular shape of the human head. Further, manual sat band placement becomes unmanageable as the number of sat bands increases. In this study we present a method which segments a high-resolution MRI to identify peripheral lipid containing regions and computes an optimized placement of sat bands in 3-D, based on the maximization of a criterion of optimality. This criterion gives a scalar that increases when the coverage of peripheral lipid containing regions increases and decreases with the loss of peripheral cortical areas. Methods: Prior to the spectroscopic scan, a high-resolution T1-weighted MP-RAGE scan (256x256, 32 slices, TR 1430) is collected and the images are downloaded to an offline workstation for segmentation and computation of sat band placement. To obtain a mask for the lipid containing regions, we use FSL[2] to extract the brain and subtract it from the original images. The core of this methodology is the optimization of the cost function C=aIL-bIo-cIb where IL, Io and Ib, are, respectively, the volumes of the intersections of the sat bands with peripheral lipid containing regions, with brain regions and the space around the head. The cost function reflects the balance between maximal lipid coverage, minimal loss of brain regions containing metabolite signals and reduction of sat band thickness outside of the head to minimize chemical shift artifacts. In order to compute the volumes of these intersections we first need to compute the convex hull described by the sat bands. This algorithm is initiated by selecting the lowest MRI slice within the (thick) spectroscopic slab as a starting point. A program developed in MATLAB 7.0 computes the optimal bands placement in 2-D for this particular slice by maximizing the cost function. The maximization is done by iteratively computing the gradient of the cost with respect to the geometrical parameters of the sat bands, which are the azimuth angle φ, the elevation angle θ, the distances of the outer and inner surfaces of each sat band from the origin d1 and d2. Since there is no analytical expression for the cost function, the gradient computation is performed by a numerical parametric approximation of first order. Since the algorithm is stable and converges, there is no justification for higher order approximations. Then, a 3-D version of the program applies the same gradient descent method to the entire lipid volume, gradually tilting the sat bands such that they follow the outer curvature of the brain. By using the output of the 2D program as the initial setting of the sat band parameters, we provide a reasonable starting point for the 3D optimization that assures the stability and convergence of the algorithm. This program provides parameters that uniquely define a set of optimally placed saturation bands in 3-D in 12 minutes computation time. In vivo experiments on 3 healthy subjects with multiple scan replications in different sessions were performed on a Siemens 4T scanner using a CP head coil. The sat band parameters were communicated to a Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) pulse sequence [3] developed under Siemens Syngo-MR via text file. A maximum of 8 outer volume suppression slices can be defined. Upon loading, the sat bands are displayed on the graphics monitor overlaid on the high resolution MRI slices. Spectroscopic imaging data were collected with the PEPSI sequence using TR: 2 sec, TE: 15msec, spatial matrix: 32x32, FOV: 240 mm, slice thickness: 15 mm, 8 averages and a total acquisition time of 8.5 minutes. A non-water suppressed reference scan was acquired for automatic phase and frequency shift correction as described previously [3]. Data were reconstructed using even-odd echo separation as described previously [3]. Spectroscopic images were computed based on LCModel [4] fitting of 15 resonances. Spectral maps were thresholded at a CRLB of 50 %. To compare the performance of the algorithm against a human operator, we use the following two metrics: (a) the integrated residual lipid signal divided by the integrated creatine signal across the entire spectroscopic slice and (b) the number of usable voxels with clearly identifiable metabolite signals. Results: Automatic placement of sat bands was reproducible across different scanning sessions in the same subject. Figure 1 shows automatically placed sat bands, which are similar to the placement by a highly trained human operator shown in Figure 2. Figure 3 shows metabolite maps obtained from LCModel fitting using automatic band placement. Figure 4 shows the corresponding maps obtained with manual sat band placement, which look very similar except for slight differences in peripheral gray matter. Table 1 shows the metrics defined above and Kramer Rao lower bounds of different metabolites for automatic and manual sat band placement, confirming that the two method yield similar results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atlas-based automated positioning of outer volume suppression slices in short-echo time 3D MR spectroscopic imaging of the human brain.

Spatial suppression of peripheral lipid-containing regions in volumetric MR spectroscopic imaging of the human brain requires placing large numbers of outer volume suppression (OVS) slices, which is time-consuming, prone to operator error and may introduce subject-dependent variability in volume coverage. We developed a novel, computationally efficient atlas-based approach for automated positio...

متن کامل

Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Breast

INTRODUCTION MR single voxel spectroscopy (MRS) to measure Choline in breast tumors has shown promise as a diagnostic adjunct to dynamic contrast-enhanced MRI exam. MRS improved the sensitivity, specificity, and accuracy for all readers, and improved the inter observer agreement between the readers [1,6]. However, single voxel spectroscopic techniques do not allow characterization of lesion het...

متن کامل

High Spatial Resolution Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Brain at 3 Tesla using 32-Channel RF Coil Array

15 mm PEPSI slice) and metabolic images of mI, Cho, Cr+PCr, Glu+Gln, NAA+NAAG and macromolecules at 0.9 ppm (MM09) measured with 0.25 cc spatial resolution, (left) before and (right) after partial volume and relaxation correction. Cho, Cr+PCr and Glu+Gln maps show strong GM/WM contrast and considerable anatomical detail, including sulcal structure (see red and yellow arrows). Fig.1:Selected cen...

متن کامل

Proton echo-planar spectroscopic imaging of J-coupled resonances in human brain at 3 and 4 Tesla.

In this multicenter study, 2D spatial mapping of J-coupled resonances at 3T and 4T was performed using short-TE (15 ms) proton echo-planar spectroscopic imaging (PEPSI). Water-suppressed (WS) data were acquired in 8.5 min with 1-cm(3) spatial resolution from a supraventricular axial slice. Optimized outer volume suppression (OVS) enabled mapping in close proximity to peripheral scalp regions. C...

متن کامل

Automatic placement of outer volume suppression slices in MR spectroscopic imaging of the human brain.

Spatial suppression of peripheral regions (outer volume suppression) is used in MR spectroscopic imaging to reduce contamination from strong lipid and water signals. The manual placement of outer volume suppression slices requires significant operator interaction, which is time consuming and introduces variability in volume coverage. Placing a large number of outer volume saturation bands for v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005