Invasive versus noninvasive hemoglobin measurement by pulse CO-Oximeter in neonates admitted to NICU

نویسندگان

  • Hetal Vora
  • Pankti Desai
چکیده

Background Total haemoglobin measurement (tHb) is one of the most commonly performed laboratory tests in patients admitted to the neonatal intensive care unit (NICU). Non invasive haemoglobin measurement is possible. In neonates this method can reduce iatrogenic blood loss. Studies performed in adults to compare haemoglobin (Hb) obtained with the use of non-invasive Hb monitor and laboratory method has shown a clinically acceptable accuracy of non-invasive Hb measurements Masimo Rainbow SET, Pulse CO‐oximetry developed by Masimo Corporation leverages 7 wavelengths and advanced signal processing technique to measure total haemoglobin (SpHb) values. The haemoglobin values measured through monitor is displayed continuously. This improves quality of care in babies by non invasive way. The monitor measures both pulse oximetry and SpHb with single probe which makes it advantageous (2) Objective. To compare transcutaneously spectroscopically measured hemoglobin values with venous hemoglobin values in neonates admitted to NICU. Study Design Prospective study in healthy preterm and term infants who were hemodynamically stable. Results Recordings were obtained from 76 stable infants (median gestational age at measurement: 36 weeks [range: 34–43 weeks]; median body weight: 1890 g [range: 1095–4360 g]). The spectroscopic haemoglobin values were corrected for inhomogeneous distribution of haemoglobin in the tissue. The venous and spectroscopic haemoglobin values were then compared by using the BlandAltman method, which gave an error of <5%. Conclusions This is a good relation between the 2 methods for measuring haemoglobin. Larger studies are required to validate this non invasive method in those with conditions that affects the perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates.

OBJECTIVE To evaluate clinical applicability of noninvasive hemoglobin (Hb) measurement with a pulse CO-oximeter in neonates. DESIGN Prospective comparison study. SETTING Neonatal ICU. PATIENTS Fifty-six preterm and term infants with median age = 20 days (range = 1-98 days) and median weight = 1,440 g (range = 530-4,230 g). INTERVENTIONS Hb measurements by Pulse CO-Oximetry (Masimo Radi...

متن کامل

Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients.

OBJECTIVE To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. DESIGN Prospective study. SETTING Surgical intensive care unit of a university teachi...

متن کامل

Use of a Combined SpO2/PtcCO2 Sensor in the Delivery Room

Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recen...

متن کامل

Reliability of new pulse CO-oximeter in victims of carbon monoxide poisoning.

STUDY OBJECTIVE The purpose of this study was to evaluate the reliability of noninvasive real-time measurement of carboxyhemoglobin (COHb) using a pulse CO-oximeter in victims of carbon monoxide poisoning (COP). METHODS During the 7-month study period, pulse CO-oximetry was measured on patients admitted to the emergency department (ED) for suspected COP. Each patient included in the study und...

متن کامل

Transforming hemoglobin measurement in trauma patients: noninvasive spot check hemoglobin.

BACKGROUND Technological advances now allow for noninvasive Hbg measurements. Previous studies have reported on the efficacy of continuous noninvasive Hgb devices. Recently, a new device, Pronto-7, a spot check pulse CO-oximeter has become available. The aim of our study was to assess noninvasive Hgb measurement in trauma patients. METHODS We performed a prospective cohort analysis of all tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014