Comparison of plasma creatinine determined with the Greiner Selective Analyser GSA II and the glomerular filtration rate.
نویسندگان
چکیده
1. Reference values for the plasma creatinine were established using the alkaline picrate method with the Greiner Selective Analyzer GSA II in relation to the Cr 51-EDTA Clearance. Individuals with normal GFR between 93 to 159 ml/min/1.73 m2 had creatinine values in men (n = 65) from 53.7 to 119.5 mumol/l (0.61 to 1.35 mg/100 ml) and in women (n = 59) from 37.7 to 107 mumol/l (0.42 to 121 mg/100 ml). 2. The creatine determinations with the GSA II were compared to those on the Technicon Analyzer, the Beckman Creatinine Analyzer, the Gemsaec-Fast Analyzer and to the enzymatic creatinine method. A good correlation (r = 0.9780-0.984) was observed. 3. With the GSA II and the enzymatic method, bilirubin showed a minor interference which was more marked with the Beckman analyzer.
منابع مشابه
SERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)
Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...
متن کاملComparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation
Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...
متن کاملComparative Assessment of Neutrophil Gelatinase-Associated Lipocalin (NGAL) and Cystatin C as Early Biomarkers for Early Detection of Renal Failure in Patients with Hypertension
Background: Hypertension is one the most common causes of chronic kidney disease (CKD). One of the major concerns in hypertensive patients is early detection of renal disorders. In the past, serum creatinine (Scr) concentration was used as a marker of kidney function, but it proffers a late reflection of reduced glomerular filtration rate. Cystatin C and neutrophil gelatinase-associated lipocal...
متن کاملEvaluation of Glomerular Filtration Rate Estimating Formulas in Diabetic Patients with Chronic Kidney Disease
Objective: Measurement of glomerular filtration rate (GFR) is the best determinant in assessment of kidney function for diagnostic and therapeutic purposes. As extremely accurate methods of GFR measurement (i.e. Inulin clearance) are expensive and Time-consuming and due to limitations of the 24 hour urine collection method, some formula have been developed for the GFR measurement. Here we have ...
متن کاملGlomerular filtration rate determination by creatinine and cystatin-C in patients with acute pyelonephritis
Background: Measurement of glomerular filtration rate (GFR) and monitoring of it in any patient on nephrotoxic drugs is very important. Recently, cystatin C (cys-C) has been introduced as a better marker for determining and monitoring renal function than creatinine especially in a mild decrease of GFR. This study was done to assess the change of GFR measurement based on serum Cys-C and creatini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biochemistry
دوره 13 1 شماره
صفحات -
تاریخ انتشار 1980