Influence of limb positioning and measurement method on the magnitude of the tibial plateau angle.
نویسندگان
چکیده
OBJECTIVE To evaluate the effect of limb positioning and measurement technique on the magnitude of the radiographically determined tibial plateau angle (R-TPA). STUDY DESIGN In vitro study, R-TPA was determined by 6 blinded observers and image measurement software. ANIMALS Five canine cadaver hind limbs. METHODS The legs were positioned on a custom-made positioning device simulating a radiographic tabletop technique in lateral recumbency. True lateral positioning was defined by superimposition of femoral and tibial condyles on the radiographic projection. Radiographs were taken while the specimens were relocated in a proximal, distal, caudal, and cranial direction with respect to the radiographic beam. For each specimen, 25 different radiographic views were obtained and 6 blinded observers determined the radiographic TPA using 2 different methods. The conventional method used precise anatomic landmarks to determine the tibial plateau. To simulate osteoarthritic changes complicating identification of these landmarks, the tangential method estimated the tibial plateau as the tangent to the central portion of the tibial plateau. After periarticular soft tissue dissection the anatomic tibial plateau angle (A-TPA) was determined. The A-TPA and the R-TPA were compared. RESULTS The R-TPA significantly decreased as limb position with respect to the X-ray beam changed from cranial proximal to caudal distal. The maximal mean radiographic R-TPA difference was 3.6 degrees with the first and 5.7 degrees with the second method. Regardless of the method used there was no significant difference between A-TPA and R-TPA in the true lateral position. In the peripheral positions, however, significant differences between anatomic and radiographic TPA were seen. CONCLUSIONS Limb positioning influenced the radiographic appearance of the tibial plateau and the magnitude of the measured TPA. Cranial and proximal positioning of the limb relative to the X-ray beam leads to overestimation whereas caudal and distal positioning leads to underestimation of the TPA. CLINICAL RELEVANCE True lateral positioning of the tibia defined by superimposition of the femoral and tibial condyles should be used for accurate TPA determination before tibial plateau leveling osteotomy.
منابع مشابه
Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملFunctional Outcome and Incidence of Osteoarthritis in Operated Tibial Plateau Fractures
Background: In the challenging tibial condyle fractures despite anatomical joint reconstruction, development ofosteoarthritis may still occur secondary to the initial articular cartilage and meniscal injury. The aim of the study wasto know incidence of osteoarthritis in our operated cases of tibial plateau fracture and to evaluate functional outcome.Methods: Our operated 60 patients of tibial p...
متن کاملInfluence of static alignment of the knee, range of tibial rotation and tibial plateau geometry on the dynamic alignment of "knee-in" and tibial rotation during single limb drop landing.
BACKGROUND Dynamic alignment of "knee-in & toe-out" is a risk factor for anterior cruciate ligament injury and is possibly influenced by static knee alignment, range of tibial rotation and tibial plateau geometry. METHODS Twenty-eight healthy women were classified into valgus, neutral and varus groups based on static alignment of their knees. A 3-dimensional motion analysis was carried out fo...
متن کاملBilateral Variability of the Quadriceps Angle (Q angle) in an Adult Indian Population
Objective(s) The objective of this study was to document and explain bilateral differences in the Q angle. Materials and Methods Two hundred limbs of healthy adult Indian volunteers were studied. The Q angle was measured using a goniometric method with the subjects supine, quadriceps relaxed and lower limbs in neutral rotation. The relative lateral placement of the tibial tuberosity with res...
متن کاملبررسی عوامل احتمالی مؤثر بر نتیجه نهایی عمل استئوتومی پروگزیمال تیبیادر استئوآرتریت کمپارتمان داخلی زانو
Introduction: Excellent results are obtained with high tibial osteotomy in patients suffering from the osteoarthritis of the medial compartment of the knee however, poor results have been reported in 10 to 50 percent of the cases. The aim of this study was to evaluate the probable factors influencing the outcome of high tibial osteotomy to let us select the proper cases for this surgery. Pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Veterinary surgery : VS
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2004