Accuracy Evaluation of CONTOUR®PLUS Compared With Four Blood Glucose Monitoring Systems
نویسندگان
چکیده
INTRODUCTION The aim of this study was to compare the accuracy of 5 blood glucose monitoring systems (BGMSs; CONTOUR(®)PLUS [CP], Accu-Chek(®) Active [ACA], Accu-Chek(®) Performa [ACP], FreeStyle Freedom™ [FF], OneTouch(®) SelectSimple™ [OTSS]). METHODS Study staff tested fingerstick samples from 106 subjects aged ≥18 years using the 5 BGMSs. Some samples were modified to achieve blood glucose concentrations throughout the measuring range. The primary endpoint was comparison of the mean absolute relative difference (MARD) from the reference value (Yellow Springs Instruments [YSI]) across the overall tested glucose range. Other endpoints were MARD in the low (≤80 mg/dL [≤4.4 mmol/L]), middle (81-180 mg/dL [4.5-10.0 mmol/L]), and high (>180 mg/dL [>10.0 mmol/L]) glucose ranges, and MARD for unmodified samples in the overall glucose range. RESULTS CONTOUR(®)PLUS had a statistically significantly lower MARD than all BGMSs across the overall tested range (27-460 mg/dL [1.5-25.5 mmol/L]) and in the high glucose range. In the low glucose range, CP had a lower MARD than all BGMSs, which was statistically significant except for ACP. For unmodified samples across the overall tested range, CP had a lower MARD than all BGMSs and was statistically significantly lower except for ACA. CONCLUSIONS CONTOUR(®)PLUS had the lowest mean difference from the reference values (by MARD) when compared with other BGMSs across multiple glucose ranges with modified and unmodified samples. FUNDING Bayer HealthCare LLC, Diabetes Care. TRIAL REGISTRATION NUMBER ClinicalTrials.gov Identifier NCT01714232.
منابع مشابه
Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial.
BACKGROUND This study evaluated differences in accuracy between the CONTOUR® NEXT EZ (EZ) blood glucose monitoring system (BGMS) and four other BGMSs [ACCU-CHEK® Aviva (ACAP), FreeStyle Freedom Lite® (FFL), ONE TOUCH® Ultra®2 (OTU2), and TRUEtrack® (TT)]. METHODS Up to three capillary blood samples (N = 393) were collected from 146 subjects with and without diabetes. One sample per subject wa...
متن کاملEvaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method
Abstract Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...
متن کاملA new test strip technology platform for self-monitoring of blood glucose.
In the management of diabetes, accuracy of devices used for self-monitoring of blood glucose (SMBG) is critical because SMBG results can affect patient diabetes-related health outcomes. A new blood glucose monitoring system (BGMS) platform has been developed that is based on the new CONTOUR® NEXT (CN) test strip. This BGMS platform uses a proprietary electron mediator and algorithm to minimize ...
متن کاملAnalysis of "Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial".
In an article in Journal of Diabetes Science and Technology, Halldorsdottir and coauthors examined the accuracy of five blood glucose monitoring systems (BGMSs) in a study sponsored by the manufacturer of the BGMS CONTOUR NEXT EZ (EZ) and found that this BGMS was the most accurate one. However, their findings must be viewed critically given that one of the BGMSs (ACCU-CHEK Aviva) was not compar...
متن کاملPreanalytic and analytic accuracy: toward more realistic and meaningful self-monitoring of blood glucose submissions for regulatory approval.
Dr. Cembrowski provides an analysis of an article by Harrison and colleagues in this issue of Journal of Diabetes Science and Technology in which the authors describe the evaluation of a new device for self-monitoring of blood glucose, the Bayer CONTOUR® blood glucose monitoring system.