Thermospray flame furnace-AAS determination of copper after on-line sorbent preconcentration using a system optimized by experimental designs.

نویسندگان

  • César Ricardo Teixeira Tarley
  • Eduardo da Costa Figueiredo
  • Geraldo Domingues Matos
چکیده

The present paper describes the on-line coupling of a flow-injection system to a new technique, thermospray flame furnace-AAS (TS-FF-AAS), for the preconcentration and determination of copper in water samples. Copper was preconcentrated onto polyurethane foam (PUF) complexed with ammonium O,O-diethyldithiophosphate (DDTP), while elution was performed using 80% (v/v) ethanol. An experimental design for optimizing the copper preconcentration system was established using a full factorial (2(4)) design without replicates for screening and a Doehlert design for optimization, studying four variables: sample pH, ammonium O,O-diethyldithiophosphate (DDTP) concentration, presence of a coil and the sampling flow rate. The results obtained from the full factorial and based on a Pareto chart indicate that only the pH and the DDTP concentration, as well as their interaction, exert influence on the system within a 95% confidence level. The proposed method provided a preconcentration factor of 65 fold, thus notably improving the detectability of TS-FF-AAS. The detection limit was 0.22 microg/dm3 and the precision, expressed as the relative standard deviation (RSD) for eight independent determinations, was 2.7 and 1.1 for copper solutions containing 5 and 30 microg/dm3, respectively. The procedure was successfully applied for copper determination in water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A sensitive method for cadmium determination using an on-line polyurethane foam preconcentration system and thermospray flame furnace atomic absorption spectrometry.

A new sensitive and low cost method for cadmium determination at microg l(-1) levels that combines an on-line preconcentration system with the thermospray flame furnace atomic absorption spectrometry technique (TS-FF-AAS) is described in this work. Cadmium is preconcentrated from an acidic medium (pH 2.0) by forming a complex with ammonium O,O-diethyldithiophosphate (DDTP), which is then adsorb...

متن کامل

Direct determination of Cu and Zn in fruit juices and bovine milk by thermospray flame furnace atomic absorption spectrometry.

In the present work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu and Zn determination in bovine milk and fruit juice samples without any pretreatment. TS-FF-AAS system was optimized and a sample volume of 300mul was injected into the carrier stream (0.014moll(-1) HNO(3) at a flow rate of 0.4mlmin(-1)), and it was introduced into a hot Ni tube. The de...

متن کامل

Preconcentration of Hg(II) with novel nano-Fe3O4- sorbents prior to determination by CVAAS

A novel, simple, sensitive and effective method has been developed for preconcentration of Hg(II) on nano-Fe3O4-DOP-ED solid-phase extraction adsorbent. In this paper, Dioctyl phthalate (DOP) was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-DOP sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a n...

متن کامل

Preconcentration of Hg(II) with novel nano-Fe3O4- sorbents prior to determination by CVAAS

A novel, simple, sensitive and effective method has been developed for preconcentration of Hg(II) on nano-Fe3O4-DOP-ED solid-phase extraction adsorbent. In this paper, Dioctyl phthalate (DOP) was used to encapsulate nano-Fe3O4 and produce a nano-Fe3O4-DOP sorbent based new sorbent was prepared. This was treated with ethylenediamine (ED) in another solvent-free procedure for the formation of a n...

متن کامل

Pii: S0039-9140(01)00362-9

A new flow injection on-line adsorption preconcentration system adapted to flame atomic absorption spectrometry (FAAS) for copper determination at the g l level was developed. Polytetrafluoroethylene (PTFE) turnings packed in a mini-column were used as sorbent material. The copper ammonium pyrrolidine dithiocarbamate (APDC) complex was sorbed on the PTFE turnings, from which it could be eluted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2005