The effect of number and distribution of unsplinted maxillary implants on the load transfer in implant-retained maxillary overdentures: an in vitro study.

نویسندگان

  • Sahar Damghani
  • Radi Masri
  • Carl F Driscoll
  • Elaine Romberg
چکیده

STATEMENT OF PROBLEM There is little information as to how the number and distribution of implants affect the amount of load transmitted to the palate in implant-retained maxillary overdentures. PURPOSE The purpose of this study was to evaluate the effect of the number and distribution of dental implants on the load transmitted to the palate. MATERIAL AND METHODS Eight implant analogues were placed in a replica of an average sized edentulous maxilla corresponding to the position of canines, first and second premolars, and first molars. The anteroposterior distance between the centers of implants in each quadrant was 8 mm. Fifteen denture bases were fabricated to fit the edentulous maxilla analogue. The denture bases were attached to the oral analogue using 6 different configurations of attachments (6 groups): Either no Locator attachments were used (control group), or the 2 most anterior attachments were attached, or 4 implants were engaged with a distance of 8, 16, or 24 mm between the centers of implants on left and right side, and finally, when all 8 attachments were activated. A force-measuring sensor was used to measure the force transmitted to the palate when a static force of 245 N was applied on the occlusal rims of the denture bases. Data (Newtons) were analyzed using 1-way ANOVA and Tukey's HSD test α=.05). RESULTS The mean (SD) amount of force measured on the palate when the overdentures were supported by 4 Locator attachments; [49.84 (26.52) at 8 mm spacing], [24.42 (15.05) at 16 mm spacing], [35.66 (22.94) at 24 mm spacing] was significantly lower than when no attachments [90.98 (20.20), control], or when 2 Locator attachments were used [76.07 (27.63)] (P<.001). When the overdentures were supported by 8 Locator attachments, the force measured on the palate [20.67(16.06) N] was significantly lower than that for the control group (P<.001), overdentures supported by 2 Locator attachments (P<.001), and overdentures supported by 4 Locator attachments when the distance between the anterior and posterior implants was 8 mm P=.006). CONCLUSIONS The distribution of implants had a significant effect on the force measured on the palate of the oral analogue in overdentures retained by Locator attachments. When the distance between the 4 implants was 16 or more mm, the load was not significantly lower than the 8 implant design, suggesting that the palate of a 4 implant-retained overdenture with a distance of 16 mm or more, does not contribute significantly to the load transfer to underlying hard palate in the in vitro analogue evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Success of Unsplinted Implant-Retained Removable Mandibular and Maxillary Overdentures: A Retrospective Study of Consecutive Cases.

Implant-retained overdentures have been provided on both splinted and freestanding implants. For the mandible, a long history shows that both approaches can be successful over the long term. For the maxilla, many clinicians prefer to splint the implants because of concerns about softer bone quality and insufficient data supporting the use of freestanding overdenture abutments. However, a few in...

متن کامل

Maxillary overdentures retained by splinted and unsplinted implants: a retrospective study.

The purpose of this retrospective study was to evaluate the clinical performance of and patients' satisfaction with maxillary overdentures retained by splinted and unsplinted implants. Patients who had been treated with maxillary implant-retained overdentures because of functional problems with conventional complete dentures were identified and invited to participate in the study. A total of 16...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

PURPOSE The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 107 6  شماره 

صفحات  -

تاریخ انتشار 2012