Molecular simulation studies of reversed-phase liquid chromatography.

نویسندگان

  • Rebecca K Lindsey
  • Jake L Rafferty
  • Becky L Eggimann
  • J Ilja Siepmann
  • Mark R Schure
چکیده

Over the past 20 years, molecular simulation methods have been applied to the modeling of reversed-phase liquid chromatography (RPLC). The purpose of these simulations was to provide a molecular-level understanding of: (i) the structure and dynamics of the bonded phase and its interface with the mobile phase, (ii) the interactions of analytes with the bonded phase, and (iii) the retention mechanism for different analytes. However, the investigation of chromatographic systems poses significant challenges for simulations with respect to the accuracy of the molecular mechanics force fields and the efficiency of the sampling algorithms. This review discusses a number of aspects concerning molecular simulation studies of RPLC systems including the historical development of the subject, the background needed to understand the two prevalent techniques, molecular dynamics (MD) and Monte Carlo (MC) methods, and the wealth of insight provided by these simulations. Examples from the literature employing MD approaches and from the authors' laboratory using MC methods are discussed. The former can provide information on chain dynamics and transport properties, whereas the latter techniques are uniquely suited for the investigation of phase and sorption equilibria that underly RPLC retention, and both can be used to elucidate the bonded-chain conformations and solvent distributions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

Reversed-phase Salt Assisted Liquid-liquid Extraction: A New Technique for Preconcentration and Determination of Crocin in Herbal Medicines by HPLC

A reversed-phase salt assisted liquid-liquid extraction (RP-SALLE) method was developed for the preconcentration and determination of trace crocin in herbal medicines by high-performance liquid chromatography (HPLC). In developed method, the roles of the aqueous and organic phases are inverted so that the analyte is extracted from the organic into the aqueous phase after salt addition and phase...

متن کامل

A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1287  شماره 

صفحات  -

تاریخ انتشار 2013