Pleth variability index combined with passive leg raising-induced pulse pressure variation to detect hypovolemia in spontaneously breathing patients.
نویسندگان
چکیده
The combination of Pleth Variability Index (PVI) and passive leg raising (PLR)-induced pulse pressure variation may help to diagnose hypovolemia in spontaneously breathing patients. In 44 subjects, PVI and Pulse Pressure (PP) variation after PLR were measured before and after induced hypovolemia (blood gift or hemodialysis session). PVI values were significantly greater after hemodialysis session or blood gift (22% vs 18%, P = 0.03); in contrast PP variation did not change significantly (7% vs 4%, P = 0.49). The accuracy of these parameters or of their combination to identify the "after hypovolemia induction" period was weak. In spontaneous ventilation, PVI value is greater after induced hypovolemia, whereas PP variation does not change significantly. The combination of PVI and PLR does not improve the accuracy of the detection of induced hypovolemia.
منابع مشابه
Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers
INTRODUCTION Pleth Variability Index (PVI) is a new algorithm that allows continuous and automatic estimation of respiratory variations in the pulse oximeter waveform amplitude. Our aim was to test its ability to detect changes in preload induced by passive leg raising (PLR) in spontaneously breathing volunteers. METHODS We conducted a prospective observational study. Twenty-five spontaneousl...
متن کاملPleth Variability Index predicts fluid responsiveness in critically ill patients
OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...
متن کاملPleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.
BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...
متن کاملChanges in pleth variability index and detection of hypotension during spinal anaesthesia for caesarean section.
Background: Hypotension occurs commonly during caesarean section under spinal anaesthesia. As the onset may be rapid, it may fail to be detected by non-invasive blood pressure (BP) measurement in a timely fashion. Pulse oximeters can continuously and non-invasively measure tissue perfusion (perfusion index (PI)) and its variation with the respiratory cycle (pleth variability index (PVI)). As wi...
متن کاملThe effect of positive end-expiratory pressure and tripled tidal volume on pleth variability index during hypovolaemia in conscious subjects: a volunteer study.
BACKGROUND The pulse oximeter measurement pleth variability index (PVI) can detect hypovolaemia during positive pressure ventilation. OBJECTIVES We studied whether PVI can detect a hypovolaemic state in spontaneously breathing humans and whether better discrimination is obtained by modifying the breathing patterns. DESIGN Experimental study. SETTING Clinical physiology department in a uni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta anaesthesiologica Belgica
دوره 61 3 شماره
صفحات -
تاریخ انتشار 2010