Balloon Sheaths for Gastrointestinal Guidance and Access: A Preliminary Phantom Study

نویسندگان

  • Xu He
  • Ji Hoon Shin
  • Hyo-Cheol Kim
  • Cheol Woong Woo
  • Sung Ha Woo
  • Won-Chan Choi
  • Jong-Gyu Kim
  • Jin-Oh Lim
  • Tae-Hyung Kim
  • Chang Jin Yoon
  • Weechang Kang
  • Ho-Young Song
چکیده

OBJECTIVE We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. MATERIALS AND METHODS The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and one was without stricture); group I was without a balloon sheath, group ll was with a deflated balloon sheath, and groups III and IV were with an inflated balloon and with the balloon in the fundus and body, respectively. Each test was performed for 2 minutes and it was repeated 10 times in each group by two researchers, and the positions reached by the catheter tip were recorded. RESULTS Both researchers had better performances with both phantoms in order of group IV, III, II and I. In group IV, both researchers advanced the catheter tip through the fourth duodenal segment in both the phantoms. In group I, however, the catheter tip never reached the third duodenal segment in both the phantoms by both the researchers. The numeric values for the four study groups were significantly different for both the phantoms (p < 0.001). A significant difference was also found between group III and IV for both phantoms (p < 0.001). CONCLUSION The balloon sheath seems to be feasible for clinical use, and it has good clinical potential for gastrointestinal guidance and access, particularly when the inflated balloon is placed in the gastric body.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Evaluation of Learning Performance of the Simplest Bovine Trans-rectal Palpation Phantom for Training Veterinary Students

Traditionally, animal exploitation in veterinary education in disciplines such as obstetrics is common worldwide. In addition, it is clear that veterinary schools are expected to provide sufficient opportunity for developing students’ necessary skill in bovine trans-rectal palpation by graduation. However, the veterinary medical education should be refined and animal exploitation in education b...

متن کامل

Access, Stents, and Urinary Drainage

Ureteral access is necessary in many endourological procedures including ureteroscopy and ureteral stenting. Technologies such as ureteral access sheaths, balloon dilators, and coaxial dilators may be helpful in facilitating ureteral access in difficult cases. This chapter describes a stenting technique that relies on fluoroscopic guidance once the initial guidewire is placed and the cystoscope...

متن کامل

Consideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation

Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...

متن کامل

Newly Designed Sheaths for Gastroduodenal Intervention: An Experimental Study in a Phantom and Dogs

OBJECTIVE To evaluate the usefulness of newly designed sheaths for gastroduodenal intervention in a gastric phantom and dogs. MATERIALS AND METHODS A regular sheath was made using a polytetrafluoroethylene tube (4 mm in diameter, 90 cm long) with a bent tip (4 cm long, 100 degree angle). For the supported type of sheath, a 5 Fr catheter was attached to a regular sheath to act as a side lumen....

متن کامل

Tracked ultrasonography snapshots enhance needle guidance for percutaneous renal access: a pilot study.

BACKGROUND AND PURPOSE Although ultrasonography-guided percutaneous nephrostomy is relatively safe, a number of factors make it challenging for inexperienced operators. A computerized needle navigation technique using tracked ultrasonography snapshots was investigated to determine whether performance of percutaneous nephrostomy by inexperienced users could be improved. METHODS Ten operators p...