Comparison of Gd-BOPTA and Gd-DPTA late gadolinium enhancement for visualizing scar, using valve enhancement as a surrogate for scar adjacent to blood

نویسندگان

  • D. C. Peters
  • R. Nezafat
  • P. Hu
  • Y. Han
  • W. J. Manning
چکیده

Introduction: Gadobenate dimeglumine (Gd-BOPTA; MultiHance; Bracco Imaging SpA, Milan, Italy) is a recently approved contrast agent with excellent properties for MR angiography (MRA) including a high relaxivity and slow clearance (1). A contrast agent with useful properties for both late gadolinium enhancement (LGE) and MRA is important for specific applications, e.g. for preand postpulmonary vein isolation (PVI) assessment (2,3), for which the MRA is essential to the electrophysiologist for planning the study, and the LGE is now a tool for assessment of potential pre-existing and RF ablation induced scar. However, the current studies suggest that the CNR between the blood and fibrosis—which is essential in imaging left atrial ablation scar or thin endocardial scar, is lower using Gd-BOPTA compared to Gd-DTPA (4,5,6), at both 0.1 and 0.2mmol/kg doses and at multiple times post injection. The purpose of our study was to investigate the blood/fibrosis CNR of Gd-BOPTA LGE vs. Gd-DTPA LGE, to assess their value for imaging scar, especially in the LA. We hypothesize that since the aortic valve and the mitral valve leaflets are fibrotic structures– usually appearing enhanced in high resolution LGE studies—they might be used as a surrogate for thin scar adjacent to blood, permitting comparison of Gd-DTPA and Gd-BOPTA, even in studies without scar. Methods: Seventeen patients with atrial fibrillation, prior to PVI, had 0.2mmol/kg Gd-BOPTA bolus injections for MRA. Fourteen to 50 minutes after injection, the 3D high resolution LGE studies were performed. Eight of these patients were imaged prior or later (usually after PVI) using Gd-DTPA. Blood SNR, blood-valve CNR were measured and valve enhancement was assessed on a 0-2 (2=enhanced, 1= slightly enhanced, 0= not visible) scale by a blinded highly experienced reader. Additionally, 16 unmatched pre-PVI studies with Gd-DTPA were also evaluated for comparison with Gd-BOPTA. Scan parameters for the LGE sequence included 3D inversion recovery GRE, fat-saturation, navigator-gating, 1.3 x 1.3 x 4mm, TR/TE/ flip =5.4ms/2.3ms/25°, 1RR between inversions, with roughly 6 minute scans (2). The relationship between blood-valve CNR and blood-scar CNR was studied in 10 patients postPVI using the same MR protocol by comparing the brightest valvular and scarred left atrial wall pixels using linear regression. Results: Figure 1 compares a pre-ablation Gd-BOPTA LGE study with a post-ablation GdDTPA LGE study. Note that the valves are visible using Gd-DPTA but not Gd-BOPTA. The SNR of scar and valvular pixels and their CNR with blood were highly correlated (SNR: R=0.96, slope= 0.8, CNR: R=0.86, slope=0.6). The valves were enhanced in 2/8 (25%) Gd-BOPTA studies compared to 7/8 (87%) Gd-DTPA studies of the same patients at a different time-points (p<0.02). Most (14/18, 87%) valves were enhanced in the unmatched Gd-DTPA studies. The CNR of the valve was 2.7 vs. 6.6 for Gd-BOPTA and Gd-DPTA, respectively, where the valve was observed. Blood pool SNR was measured to be 33 ±14 vs. 17 ±9 (p=0.003) for Gd-BOPTA vs. GdDTPA. The valve enhancement score was 0.6 for pre-PVI studies with Gd-BOPTA, and 1.3 in the un-matched Gd-DTPA studies (p=0.01), and 0.6 vs. 1.6 (p=0.02) in the matched studies. Figure 2 shows the relationship between imaging delay post injection and valve enhancement, and compares the Gd-DTPA and Gd-BOPTA studies. For Gd-DTPA, the delays were 21±5, and 16±2 minutes, for studies with ranking of 2 (enhanced) and 1 (slightly enhanced) respectively (p=0.11). There was no relationship between valve enhancement and time delay for Gd-BOPTA studies (average delay 31±11minutes). Conclusions: Valves are fibrotic, and frequently appear enhanced on high resolution LGE images, with SNR and blood CNR correlated to those of scar—therefore, they serve as a useful surrogate for scar. From this valve enhancement study, we infer that Gd-DTPA LGE acquired with 0.2mmol/kg injection provides improved visualization of any scar abutting blood, such as in the left atrium after PVI, compared to Gd-BOPTA at similar time points and dose. This is likely due to the previously reported lack of a T1 difference between blood and scar using GdBOPTA. Longer delays might be superior for visualizing thin scar with Gd-DTPA (Figure 2). 1. Kirchin MA et al. Invest Radiol. 1998;33:798–809. 2. Peters DC et al. JACC Cardiovasc Imaging 2009; 2:308-316.3. McGann CJ et al. J Am Coll Cardiol 2008; 52:1263-1271.4. GA. Krombach et al. Eur Radiol (2009) 19: 2136–2146 5. Bauner et al. Invest Radiology 2008 44:95 6. Schlosser et al. Radiology 2005; 236:1041–1046. Pre PVI Gd-BOPTA Post-PVI Gd DTPA valves

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMR myocardial infarct evaluation in a canine model by three different contrast agents

We evaluated R1 curves, CNR and scar visualization and quantification in a dog model of myocardial infarction by CMR, using three different contrast agents: Gadopentate dimeglumine (Gd-DTPA, Magnevist), Gadobenate dimeglumine (Gd-BOPTA, MultiHance), and Gadofosveset (Ablavar). Gd-DTPA showed better characteristics for myocardial scar visualization and quantification. Gadofosveset demonstrated l...

متن کامل

Comparison of gadobenate dimeglumine and gadopentetate dimeglumine: a study of MR imaging and inductively coupled plasma atomic emission spectroscopy in rat brain tumors.

BACKGROUND AND PURPOSE After the advent of extracellular contrast media, hepatobiliary-specific gadolinium chelates were developed to improve the diagnostic value of MR imaging of the liver. Gadobenate dimeglumine (Gd-BOPTA) is a new paramagnetic contrast agent with partial biliary excretion that produces prolonged enhancement of liver parenchyma on T1-weighted images. However, whether Gd-BOPTA...

متن کامل

Contrast-enhanced magnetic resonance cholangiography with Gd-BOPTA and Gd-EOB-DTPA in healthy subjects.

PURPOSE To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences betwee...

متن کامل

Gd-DTPA enhancement of posterior epidural scar: an experimental model.

Because of the tremendous clinical and physiological importance of anterior epidural scar, an easily produced and reproducible model to assess potential pathways for lessening its formation is a necessity. We speculated whether posterior epidural scar (produced by the less complex surgery of laminectomy alone) could be considered equivalent to anterior scar from an imaging standpoint; that is, ...

متن کامل

Contrast-Enhanced Magnetic Resonance Angiography in Rats with Gadobenate Dimeglumine at 3T

This study aimed to investigate the magnetic resonance (MR) signal enhancement ratio (ER) of contrast-enhanced MR angiography (CE-MRA) in normal rats with gadobenate dimeglumine (Gd-BOPTA) using a clinical 3T scanner and an extremity coil. The relaxivities of Gd-BOPTA with saline only and with 4.5% human serum albumin (HSA) were also measured. Compared with Gadolinium diethylenetriaminepentaace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009