Comparison of Colilert-18 with miniaturised most probable number method for monitoring of Escherichia coli in bathing water.

نویسندگان

  • Ananda Tiwari
  • Seppo I Niemelä
  • Asko Vepsäläinen
  • Jarkko Rapala
  • Seija Kalso
  • Tarja Pitkänen
چکیده

The purpose of this equivalence study was to compare an alternative method, Colilert-18 Quanti-Tray (ISO 9308-2) with the European bathing water directive (2006/7/EC) reference method, the miniaturised most probable number (MMPN) method (ISO 9308-3), for the analysis of Escherichia coli. Six laboratories analysed a total of 263 bathing water samples in Finland. The comparison was carried out according to ISO 17994:2004. The recovery of E. coli using the Colilert-18 method was 7.0% and 8.6% lower than that of the MMPN method after 48 hours and 72 hours of incubation, respectively. The confirmation rate of presumptive E. coli-positive wells in the Colilert-18 and MMPN methods was high (97.8% and 98.0%, respectively). However, the testing of presumptive E. coli-negative but coliform bacteria-positive (yellow but not fluorescent) Colilert-18 wells revealed 7.3% false negative results. There were more false negatives in the naturally contaminated waters than in the samples spiked with waste water. The difference between the recovery of Colilert-18 and the MMPN method was considered not significant, and subsequently the methods are considered as equivalent for bathing water quality monitoring in Finland. Future bathing water method equivalence verification studies may use the data reported herein. The laboratories should make sure that any wells showing even minor fluorescence will be determined as positive for E. coli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three Methods of Pour Plate (PP) ، Most Probable Number (MPN)and Membrane Filter (MF) for Detection of Escherichia coliin Well Water Samples in Tehran's Parks in 2010

Abstract Background and objectives: Water-born diseases are typically caused by pathogens transmitted by orofecal way. Because it is no practical and no economical and also it is time-consuming to find water-born pathogens in water reservoirs, the laboratory studies are performed on the basis of indicator microorganism. Escherichia coli is considered as the most important indicator bacterium fo...

متن کامل

Improved methods for detecting E. coli and coliforms in drinking water: AFNOR validation of Colilert-18/Quanti-Tray

• Per AFNOR Certification guidelines, a preliminary study was conducted where the relative accuracy, linearity, detection and quantification limits, selectivity (inclusivity and exclusivity) and practicability of the Colilert-18/Quanti-Tray method were assessed using samples of distribution water and fountain water spiked with strains of both coliform bacteria and E. coli. All the assessed perf...

متن کامل

Microbial Monitoring of Surface Water in South Africa: An Overview

Infrastructural problems force South African households to supplement their drinking water consumption from water resources of inadequate microbial quality. Microbial water quality monitoring is currently based on the Colilert®18 system which leads to rapidly available results. Using Escherichia coli as the indicator microorganism limits the influence of environmental sources on the reported re...

متن کامل

Marine bacteria cause false-positive results in the Colilert-18 rapid identification test for Escherichia coli in Florida waters.

The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-1...

متن کامل

EU Drinking Water Directive reference methods for enumeration of total coliforms and Escherichia coli compared with alternative methods.

AIMS The reference methods for enumeration of total coliforms and Escherichia coli as stated in the European Drinking Water Directive were compared with alternative methods. METHODS AND RESULTS Laboratories used the reference method on Lactose TTC agar (LTTC), the Colilert/18 system, Laurysulphate Agar (LSA), Chromocult Coliform Agar and the E. coli Direct Plating (DP) method. They enumerated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of water and health

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2016