Laser in situ Keratomileusis Corneal Flap Creation With the Nidek MK-2000 and the Carriazo Barraquer Microkeratomes.

نویسندگان

  • A Vongthongsri
  • S Srivannaboon
  • O Horatanaruang
  • P Nariptaphan
چکیده

PURPOSE To evaluate the performance of the Nidek MK-2000 and the LSK Carriazo Barraquer microkeratomes in the creation of corneal flaps for laser in situ keratomileusis (LASLK). METHODS A prospective randomized study of 55 eyes of 30 patients who underwent LASLK was performed. Twelve corneal flaps were created hy the Nidek MK-2000 microkeratome (160-/«n head), 30 corneal flaps by the Carriazo Barraquer 160-¿m head microkeratome, and 13 corneal flaps by the Carriazo Barraquer 180-/tm head microkeratome. Flap thickness (evaluated by ultrasonic pachymetry), flap diameter, hinge size, and hinge-to-centerof-pupil distance were measured. RESULTS For the Nidek MK-2000 microkeratome, mean flap thickness was 149.58 ± 25.61 µ?? (range, 94 to 186 /im), flap diameter was 8.81 ± 0.34 mm (range, 8.4 to 9.1 mm), hinge size was 4.31 ± 0.45 mm (range, 3.9 to 4.8 mm), and hinge-to-centerof-pupil distance was 3.79 ± 0.70 mm (range, 3.9 to 4.7 mm). For the Carriazo Barraquer 160-/im head microkeratome, mean flap thickness was 123.9 ± 22.28 jttm (range, 104 to 155 /an), flap diameter was 9.08 ± 0.44 mm (range, 8.7 to 11 mm), hinge size was 4.04 ± 0.61 mm (range, 4 to 6 mm), and hinge-tocenter-of-pupil distance was 4.37 ± 0.24 mm (range, 4 to 4.5 mm). For the Carriazo Barraquer I80-/«n head microkeratome, mean flap thickness was 167.23 ± 24.92 ^m (range, 145 to 198 /nn), flap diameter was 9.12 ± 0.18 mm (range, 9 to 9.4 mm), hinge size was 4.21 ± 0.39 mm (range, 4 to 5 mm), and hinge-to-center-of-pupil distance was 4.47 ± 0.24 mm (range, 4.2 to 4.7 mm). There was no correlation between corneal curvature and flap diameter. No case was aborted due to improper corneal flap creation. An epithelial defect was found in 5 eyes after reverse movement of the Nidek MK2000 microkeratome. CONCLUSION The Nidek MK-2000 and the Carriazo Barraquer microkeratomes were effective, safe, and reliable in the creation of corneal flaps for LASLK. [J Refract Surg 2000;16(suppl): S272-S275].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis

PURPOSE Femtosecond lasers have become the standard for laser-assisted in situ keratomileusis (LASIK) flap creation, but advanced mechanical microkeratomes are still an alternative, more cost-effective way to create the flap. The SCHWIND Carriazo-Pendular microkeratome is one of the most commonly used microkeratomes. The influence of different cutting parameters (head-advance speeds, cutting he...

متن کامل

Quality assessment model of 3 different microkeratomes through confocal microscopy.

PURPOSE To study the quality of the cut created by 3 microkeratomes from 2 different generations using corneal confocal microscopy. SETTING Department of Refractive Surgery, Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS Two different studies were conducted: Study 1 and Study 2. Study 1 was a prospective analysis using confocal microscopy examination data from 2 reference gro...

متن کامل

Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper.

PURPOSE The purpose of this study was to retrospectively compare the incidence of intraoperative flap complications, such as partial flaps, donut-shaped flaps, central corneal cuts, and complete caps with the Hansatome and Automated Corneal Shaper (ACS) microkeratomes. METHODS All laser in situ keratomileusis (LASIK) procedures performed by a single surgeon with the Hansatome or Automated Cor...

متن کامل

Factors Influencing Intraocular Pressure Changes after Laser In Situ Keratomileusis with Flaps Created by Femtosecond Laser or Mechanical Microkeratome

The aim of this study is to describe factors that influence the measured intraocular pressure (IOP) change and to develop a predictive model after myopic laser in situ keratomileusis (LASIK) with a femtosecond (FS) laser or a microkeratome (MK). We retrospectively reviewed preoperative, intraoperative, and 12-month postoperative medical records in 2485 eyes of 1309 patients who underwent LASIK ...

متن کامل

Comparison of two microkeratome systems.

BACKGROUND Microkeratomes are currently used for keratomiluesis in situ (automated lamellar keratoplasty) for myopia and hyperopia and for laser in situ keratomileusis (LASIK). Visual and refractive complications have been reported with these refractive surgical procedures. We compared two microkeratomes in their ability to resect corneal lamellae to gain insight into possible mechanism(s) of r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 16 2 Suppl  شماره 

صفحات  -

تاریخ انتشار 2000