Comparison Between Spectral-Domain and Swept-Source Optical Coherence Tomography Angiographic Imaging of Choroidal Neovascularization
نویسندگان
چکیده
Purpose The purpose of this study was to compare imaging of choroidal neovascularization (CNV) using swept-source (SS) and spectral-domain (SD) optical coherence tomography angiography (OCTA). Methods Optical coherence tomography angiography was performed using a 100-kHz SS-OCT instrument and a 68-kHz SD-OCTA instrument (Carl Zeiss Meditec, Inc.). Both 3 × 3- and 6 × 6-mm2 scans were obtained on both instruments. The 3 × 3-mm2 SS-OCTA scans consisted of 300 A-scans per B-scan at 300 B-scan positions, and the SD-OCTA scans consisted of 245 A-scans at 245 B-scan positions. The 6 × 6-mm2 SS-OCTA scans consisted of 420 A-scans per B-scan at 420 B-scan positions, and the SD-OCTA scans consisted of 350 A-scans and 350 B-scan positions. B-scans were repeated four times at each position in the 3 × 3-mm2 scans and twice in the 6 × 6-mm2 scans. Choroidal neovascularization was excluded if not fully contained within the 3 × 3-mm2 scans. The same algorithm was used to detect CNV on both instruments. Two graders outlined the CNV, and the lesion areas were compared between instruments. Results Twenty-seven consecutive eyes from 23 patients were analyzed. For the 3 × 3-mm2 scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.17 and 1.01 mm2, respectively (P = 0.047). For the 6 × 6-mm2 scans, the mean lesion areas for the SS-OCTA and SD-OCTA instruments were 1.24 and 0.74 mm2 (P = 0.003). Conclusions The areas of CNV tended to be larger when imaged with SS-OCTA than with SD-OCTA, and this difference was greater for the 6 × 6-mm2 scans.
منابع مشابه
Comparison of choroidal thickness using swept-source and spectral-domain optical coherence tomography in normal Indian eyes
BACKGROUND/AIMS Choroidal thickness measurements are reported to differ between spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT). The aim of this study was to assess the comparability of choroidal thickness measurements using SS-OCT and SD-OCT devices among normal participants. MATERIALS AND METHODS This was a prospective study of 31 (62 eyes) normal partici...
متن کاملThe expanded spectrum of focal choroidal excavation.
OBJECTIVE To describe the clinical and imaging findings in patients with focal choroidal excavation. METHODS Retrospective observational case series. The medical records of 12 patients (13 eyes) with focal choroidal excavation were reviewed. Clinical histories and imaging findings (including color photography, fundus autofluorescence imaging, fluorescein angiography, indocyanine green angiogr...
متن کاملAutomated Quantitation of Choroidal Neovascularization: A Comparison Study Between Spectral-Domain and Swept-Source OCT Angiograms
Purpose To compare the lesion sizes of choroidal neovascularization (CNV) imaged with spectral-domain (SD) and swept-source (SS) optical coherence tomography angiography (OCTA) and measured using an automated detection algorithm. Methods Patients diagnosed with CNV were imaged by SD-OCTA and SS-OCTA systems using 3 × 3-mm and 6 × 6-mm scans. The complex optical microangiography (OMAGC) algori...
متن کاملSwept-source optical coherence tomography angiography for choroidal neovascularization after bevacizumab and photodynamic therapy
Purpose To report the swept-source optical coherence tomography angiography (SS-OCTA) findings after bevacizumab anti-vascular endothelial growth factor (anti-VEGF) and full-fluence photodynamic therapy (PDT) for choroidal neovascularization. Design Case report. Methods An 87-year-old, Chinese male presented with a shadow and decreased vision to 20/160 in his left eye (OS). Clinical examina...
متن کاملSpectral-domain optical coherence tomography findings in polypoidal choroidal vasculopathy suggest a type 1 neovascular growth pattern
PURPOSE To report spectral-domain optical coherence tomography (SD-OCT) findings in polypoidal choroidal vasculopathy (PCV). PATIENTS AND METHODS Seventeen eyes of 15 consecutive patients diagnosed with PCV based on typical clinical and angiographic findings were imaged with macular SD-OCT including line scans passing through the polyps. RESULTS SD-OCT findings included typical and atypical...
متن کامل