Reply to Gratiy et al.
نویسندگان
چکیده
TO THE EDITOR: Gratiy et al. (2013) proposed two alternative explanations for the nonbalanced current source density (CSD) estimates in Riera et al. (2012). Their commentary was based on a particular interpretation of the role played by the Ampere-Maxwell Law in the genesis of the electric fields for macroscopic media. In this Reply, we will provide further information to stimulate the debate in the community.
منابع مشابه
Reply to Gratiy et al.
homogeneous locally neutral medium,we have two independent current conservation laws: one law applies to the freecharge current i and another one applies to the displacement current i. Note that in a homogeneous medium i is not necessarily negligible, but the application of the current conservation law on i can be done independently of the existence of i because the two laws are independent. In...
متن کاملInstantaneous Charge Unbalance in the Brain: a Result from Procedural Errors or an Authentic
TO THE EDITOR: Gratiy et al. (2013) proposed two alternative explanations for the nonbalanced current source density (CSD) estimates in Riera et al. (2012). Their commentary was based on a particular interpretation of the role played by the Ampere-Maxwell Law in the genesis of the electric fields for macroscopic media. In this Reply, we will provide further information to stimulate the debate i...
متن کاملReply to “A Critical Review of Proximal Fibular Osteotomy for Knee Osteoarthritis”
Proximal fibular osteotomy is a surgical procedure that has evoked significant interest and controversy in the recent past. Vaishya et al have made a significant effort in compiling the available evidence on the topic. However, we would like to make some significant suggestions and additions to the findings in their manuscript.
متن کاملEnvironmental gamma radiation: a comment (Letter to the Editor)
Editor, I read the recent publication by Toossi et al. with a great interest (1). Toossi et al. concluded that “Average gonad and bone marrow doses for North Khorasan, Boshehr and Hormozgan provinces were less than the corresponding values for normal area (2).” There are some facts on this report to be concerned. I agree that the detected levels might be high in the mentioned area, but th...
متن کاملLetter to editor
Dear Prof. Mozdarani,I would like to discuss about some important aspects regarding the article published in, "Iran. J. Radiat. Res., 2012 10(2): 89-94“ with title of “Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode" by Ghavami et al. (1), so according to journal policy and in suitable manner please ask the authors to rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of neurophysiology
دوره 109 6 شماره
صفحات -
تاریخ انتشار 2013