A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.
نویسندگان
چکیده
A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in three-dimensional (3D) motion. The Von Mises stress distribution in the internal fixators was evaluated, as well as the range of motion (ROM) and facet joint force. The models were generated and analyzed by mimics, geomagic studio, and ansys software. The intact model of the lower cervical spine consisted of 286,382 elements. The model was validated against previously reported cadaveric experimental data. In the ASPS model, stress was concentrated at the connection between the screw and plate and the connection between the titanium mesh and adjacent vertebral body. In the AVBS model, stress was evenly distributed. Compared to the intact cervical spine model, the ROM of the whole specimen after fixation with both constructs is decreased by approximately 3 deg. ROM of adjacent segments is increased by approximately 5 deg. Facet joint force of the ASPS and AVBS models was higher than those of the intact cervical spine model, especially in extension and lateral bending. AVBS fixation represents a novel reconstruction approach for the lower cervical spine. AVBS provides better stability and lower risk for internal fixator failure compared with traditional ASPS fixation.
منابع مشابه
Anterior Transpedicular Screw-Plate System Fixation in the Lower Cervical Spine Fracture Complicated by Spinal Cord Injury: A Case Report
A multilevel contiguous fracture of the subaxial cervical spine represents the severe trauma, and anterior plate fixation with anterior transpedicular screw fixation is a new and reliable fixation pattern for the treat-ment of acute spinal cord injury (ASCI). We present a case of multilevel contiguous fractures in the lower cervical spine without obvious posterior ligamentous complex injury, bu...
متن کاملAccuracy of fluoroscopy versus computer-assisted navigation for the placement of anterior cervical pedicle screws.
STUDY DESIGN Randomized laboratory cadaver study. OBJECTIVE The objective of this study was to determine the accuracy of anterior transpedicular screw placement in the cervical spine using conventional fluoroscopy versus computer-assisted navigation. SUMMARY OF BACKGROUND DATA Traditionally, global cervical instability has required anterior and posterior fixation due to the superior biomech...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملA Biomechanical Comparison of Three Different Posterior Fixation Constructs Used for C6–C7 Cervical Spine Immobilization: A Finite Element Study
The intralaminar screw construct has been recently introduced in C6-C7 fixation. The aim of the study is to compare the stability afforded by three different C7 posterior fixation techniques using a three-dimensional finite element model of a C6-C7 cervical spine motion segment. Finite element models representing three different cervical anchor types (C7 intralaminar screw, C7 lateral mass scre...
متن کاملComparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review
OBJECTIVES No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, large...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 139 6 شماره
صفحات -
تاریخ انتشار 2017