Ultrasonic Flow Measurement with Integrated Temperature Measurement Compensation

نویسندگان

  • Benjamin E. McDonald
  • Lei Sui
چکیده

Compensation for ultrasonic flow measurement has increasingly become the trend for applications that call for higher accuracy and tighter repeatability. Temperature is a variable that tends to have a significant impact on performance. Geometric dimension changes due to thermal expansion and contraction, as well as fluid dynamics, are impacted by temperature and thus have an influence on overall system accuracy. This paper presents a new method for measuring temperature by taking advantage of well characterized material properties that change with temperature and utilizing existing system capability. Integrated temperature measurement can be included as part of the diagnostic support package and used for compensation by using existing capability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of ultrasonic distance-measuring system using temperature compensation methods

This document presents the principle of ultrasonic distance measurement is described, the main error sources of ultrasonic distance measurement are analyzed also. A method of improving precision of ultrasonic distance measurement in air, in which the transmission speed of ultrasonic wave if corrected by measured air temperature and the forward edge of receive wave can be determined accurately b...

متن کامل

An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset

This paper proposes a new, improved method for water flow metering. It applies to a transit time ultrasonic flow meter device. In principle, the flow of a given liquid in a pipe is obtained by measuring the transit times of an ultrasonic wave in the upstream and downstream directions. The difference between these times is, in theory, linearly proportional to the liquid flow velocity. However, t...

متن کامل

A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The e...

متن کامل

Fundamentals of Multipath Ultrasonic flow meters for Gas Measurement

This paper discusses fundamental principles of ultrasonic gas flow meters used for measurement of natural gas. A review of an ultrasonic meter’s operation and the equations used to determine actual volumetric flow is presented. The ultrasonic flow meter’s diagnostic capability will also be briefly presented. Further, diagnostic data, in conjunction with gas composition, pressure and temperature...

متن کامل

A simple and novel method for acoustic streaming power measurement of ultrasonic horn

Ultrasonic horn with transfer of acoustic wave into an aqueous solution results in unique properties. When, transfer of sound wave into a liquid results in liquid movement in the direction of wave propagation which gradually loses its energy due to the viscous friction. This wave motion induces a flow which is known as acoustic streaming or micro-streaming. In this article, a simple innovative ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014