Accuracy of needle implantation in brachytherapy using a medical AR system – a phantom study

نویسندگان

  • Stefan Wesarg
  • Evelyn A. Firle
  • Bernd Schwald
  • Helmut Seibert
  • Pawel Zogal
  • Sandra Roeddiger
چکیده

Brachytherapy is the treatment method of choice for patients with a tumor relapse after a radiation therapy with external beams or tumors in regions with sensitive surrounding organs-at-risk, e. g. prostate tumors. The standard needle implantation procedure in brachytherapy uses pre-operatively acquired image data displayed as slices on a monitor beneath the operation table. Since this information allows only a rough orientation for the surgeon, the position of the needles has to be verified repeatedly during the intervention. Within the project Medarpa a transparent display being the core component of a medical Augmented Reality (AR) system has been developed. There, pre-operatively acquired image data is displayed together with the position of the tracked instrument allowing a navigated implantation of the brachytherapy needles. The surgeon is enabled to see the anatomical information as well as the virtual instrument in front of the operation area. Thus, the Medarpa system serves as ‘window into the patient’. This paper deals with the results of first clinical trials of the system. Phantoms have been used for evaluating the achieved accuracy of the needle implantation. This has been done by comparing the output of the system (instrument positions relative to the phantom) with the real positions of the needles measured by means of a verification CT scan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel phantom design for brachytherapy quality assurance

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

متن کامل

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

RadVision integration with TRUS robot for Brachytherapy

The main goal of this project is to integrate the RadVision treatment planning software with the (Trans-Rectal Ultrasound ) or TRUS robot. The TRUS robot is used in place of a physical template for placing the radioactive seeds in prostate brachytherapy, a treatment for prostate cancer. This integration should allow the surgeon to position the needle of the robot more accurately with the new sy...

متن کامل

Accuracy Evaluation of Oncentraâ„¢ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

متن کامل

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004