Comparison of imaging protocols for 18F-FDG PET/CT in overweight patients: optimizing scan duration versus administered dose.
نویسندگان
چکیده
UNLABELLED The quality of (18)F-FDG PET/CT images of overweight patients is often degraded. We evaluated the effect of optimizing injected dose or acquisition time on the quality of images of overweight patients using lutetium oxyorthosilicate PET/CT with high-performance detector electronics. METHODS We initially retrospectively measured radioactivity concentrations and signal-to-noise ratios (SNRs) in the liver relative to body weight for 80 patients who had undergone (18)F-FDG PET/CT according to our standard protocol (injected dose, 3.7 MBq/kg; acquisition time, 2 min/bed position). The patients were grouped (n = 20 per group) according to baseline body weight as G1 (or=85 kg). We compared the SNRs of G1 with those of G2, G3, and G4 and calculated the ratio squared as a factor to correct the acquisition parameters for overweight patients. We then prospectively enrolled 120 patients according to the same body weight criteria. We multiplied the correction factors to optimize injected doses or acquisition times and defined dose-adjusted groups (n = 20 per group) and time-adjusted groups (n = 20 per group). G2 dose was defined as 5.59 +/- 0.19 MBq/kg, G3 dose as 7.29 +/- 0.33 MBq/kg, and G4 dose as 8.88 +/- 0.43 MBq/kg. G2 time was defined as 3 min/bed position, G3 time as 4 min/bed position, and G4 time as 5 min/bed position. RESULTS Although liver activities did not significantly differ among G1 through G4 irrespective of patient weight, SNR progressively decreased as patient weight increased. The liver activities of G2 dose, G3 dose, and G4 dose were, respectively, 1.4-, 1.9-, and 2.5-fold higher than those of the baseline counterparts. Nevertheless, the increased liver activities of G2 dose, G3 dose, and G4 dose did not significantly affect SNR, compared with the baseline groups. In contrast, the SNR of G4 time was significantly higher than that of G4. CONCLUSION Our findings suggest that the quality of images acquired from heavier patients can be maintained only by scanning for longer periods. Increasing the dose per kilogram of body weight did not improve the quality of lutetium oxyorthosilicate PET/CT images.
منابع مشابه
Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer
Objective(s): Small cell lung cancer (SCLC) is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM) staging of SCLC, compared to the conventional computed tomography (CT) scan and its potential role as a prognosticat...
متن کاملImplementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...
متن کاملA Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.
Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...
متن کاملDiagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary
Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...
متن کاملClinical Impact of 18F-FDG PET/CT on the Management of Gynecologic Cancers: One Center Experience
Objective(s): We aim to investigate the clinical impact of 18F-FDG PET/CT in managing patients with gynecological malignancies and pelvic or extrapelvic lymph nodes that are of equivocal significance on conventional imaging.Methods: We retrospectively evaluated 18F-FDG PET/CT scans of patients with gynecologic tumors who were referred to King Hussein Cancer Center from January 2010 to August 20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 50 6 شماره
صفحات -
تاریخ انتشار 2009