Parallel imaging of the upper airway with a novel 16-channel tongue coil
نویسندگان
چکیده
Introduction: Recently, Hayes et al. proposed novel designs for 12and 16-channel tongue coil arrays and demonstrated their ability to improve tongue SNR [1]. The coil array provides highly localized sensitivity that includes the tongue and upper airway. In this work, we measure and analyze the SNR and g-factor of the 16-channel tongue coil for several tissues of interest, in a mid-sagittal scan plane. We examine the feasibility of parallel imaging using undersampled 2DFT and 2DPR with a range of acceleration factors. Methods: Experiments were performed on a GE Signa HDx 3.0T MRI scanner. Three coils were compared: single-channel birdcage transmit/receive coil, 8-channel neurovascular (NV) array receive-only, and 16-channel tongue array receive-only. Imaging parameters were: 3DFT gradient echo, TE=2.1 ms, TR=3.9 ms, 1.88x1.88x2.50 mm spatial resolution, 24x24x18 cm FOV. The subject held their mouth closed without swallowing during each 30 second scan. The noise covariance matrix was calculated from data acquired with the RF turned off. Coil sensitivity maps for each coil element were calculated by dividing each coil image by a body coil image. Nine ROIs (see Table 1) were selected and their SNR/gfactors were evaluated separately with respect to different reduction factors R=1 to 6. For Cartesian SENSE, the phase encode direction was anteriorposterior (A-P), SNR was calculated using the B1 weighted combining method [2,3], and g-factors were calculated pixel-by-pixel [4]. For radial SENSE, g-factor maps were determined via Monte-Carlo simulation [5]. A k-space dataset with white Gaussian noise was generated for each coil element and image was reconstructed based on an iterative conjugate-gradient algorithm [6]. The iterative reconstruction was terminated at the 50 iteration. This process was repeated 200 times. The g-factor map was taken as the standard deviation of the pixel values of the images resulting from all 200 realizations [5]. Results: Table 1 shows SNR values for 9 different ROIs with 3 different coil arrays. The 16-ch tongue coil produced an 8.8-fold and 19-fold increase in the SNR of the lower lip ROI over the 8-ch NV and birdcage coil, respectively. A 9.3-fold SNR drop-off was observed from lower lip to pharyngeal wall (i.e., the A-P direction) in the 16-ch tongue coil. Figure 1 shows g-factor values for 2DFT and 2DPR trajectories with 8-ch NV array and 16-ch tongue array. The g-factor values for 2DFT were substantially lower for the 16-ch tongue array compared to the 8-ch NV array (e.g., the average g-factor was 40% lower for reduction factor 4). The g-factor values for 2DPR were lower than those for 2DFT for both the 8-ch NV and 16ch tongue coils. Figure 2 contains images reconstructed via SENSE (R=4) from the Cartesian sampled data. Compared to the 8-ch NV image the 16ch tongue array image exhibits substantially higher SNR and overall image quality. Discussion: The 16-ch tongue coil has provided substantial improvement in SNR compared to existing coils and produced acceptable image quality with a SENSE reduction factor 4 when using 2DFT trajectories. The use of this coil will significantly improve MRI for speech production research and other investigations of the upper airway. The use of 2DPR or other non-Cartesian trajectories with parallel imaging may be useful for improving the spatio-temporal resolution of real-time MRI of speech [7]. Acknowledgments: This work was supported by NIH Grant R01 DC007124-01. References: [1] Hayes et al., ISMRM, p449, 2007, [2] Kellman et al., MRM:54:1439-1447, 2005, [3] Roemer et al., MRM:16:192-225, 1990, [4] Pruessmann et al., MRM:42:952-962, 1999, [5] Eggers et al., ISMRM, p2429, 2005, [6] Pruessmann et al., MRM:46:638-651, 2001, [7] Narayanan et al., J.Acoust.Soc.Am.:115(4):1771-1776, 2004.
منابع مشابه
Novel 16-channel receive coil array for accelerated upper airway MRI at 3 Tesla.
Upper airway MRI can provide a noninvasive assessment of speech and swallowing disorders and sleep apnea. Recent work has demonstrated the value of high-resolution three-dimensional imaging and dynamic two-dimensional imaging and the importance of further improvements in spatio-temporal resolution. The purpose of the study was to describe a novel 16-channel 3 Tesla receive coil that is highly s...
متن کامل789 High spatio - temporal resolution multi - slice real time MRI of speech using golden angle spiral imaging with constrained reconstruction , parallel imaging , and a novel upper airway coil
High spatio-temporal resolution multi-slice real time MRI of speech using golden angle spiral imaging with constrained reconstruction, parallel imaging, and a novel upper airway coil Sajan Goud Lingala, Yinghua Zhu, Yoon-Chul Kim, Asterios Toutios, Shrikanth Narayanan, and Krishna S Nayak Electrical Engineering, University of Southern California, Los Angeles, California, United States, Samsung ...
متن کاملUltra-high resolution 3D upper airway MRI with compressed sensing and parallel imaging
Introduction: 3D MR imaging of the vocal tract during sustained sound production provides valuable insight into the shaping and modeling of vocal articulation [1]. Recently, high spatial resolution 3D imaging of vocal tract shaping (with no repetitions of the same sound) was demonstrated [2] by utilizing compressed sensing MRI [3] with a single channel receive coil. When imaging with multiple c...
متن کاملMultiple-Animal MR Imaging Performed using a 3-Tesla Whole-body Scanner: A Feasibility Study using a 16-Channel Array Coil
before (left) and after (right) signal intensity correction. The images of the other 2 rats were simultaneously obtained and were of comparable quality (not shown). Fig.1. Sixteen-channel coil dedicated for small animal MRI. An array comprises 8 5-cm-circular coils (a). The 16-channel coil has 2 sets of 8-array coils in the upper and lower parts (b). A white bar on the top is used to adjust the...
متن کاملDesign of a Coil System for Hyperpolarized 3He Human Lung Imaging
Introduction: Clinic hyperpolarized He gas human lung imaging has been widely conducted in recent years. Multi-channel coil designed for human lung parallel imaging has been reported [1] to accelerate the imaging speed. Large asymmetric birdcage coil were also developed to replace the single loop coil for better B1 homogeneity [2]. This work presents a design of a coil system for hyperpolarized...
متن کامل