Randomized comparison of carbon ion-implanted stent versus bare metal stent in coronary artery disease: the Asian Pacific Multicenter Arthos Stent Study (PASS) trial.
نویسندگان
چکیده
BACKGROUND Heavy metal ions can cause allergic and inflammatory reactions that might be associated with in-stent restenosis. This randomized multicenter clinical study was designed to determine if carbon ion-implanted stents reduce luminal late loss by blocking heavy metal ion diffusion into the surrounding tissue. METHODS A total of 225 patients with 230 native coronary lesions were randomly assigned to receive either a carbon ion-implanted Arthos Inert stent (group 1, n = 113) or a bare metal Arthos stent (group 2, n = 117). The primary endpoint was in-stent luminal late loss at 6-month angiographic follow-up, and the secondary endpoints were the 6-month angiographic restenosis rate and the occurrence of the major adverse cardiac events (MACE) including death, nonfatal myocardial infarction, and target lesion revascularization at 12 months. RESULTS The baseline characteristics were similar in the 2 groups. In-hospital events did not occur in any patients. Angiographic follow-up at 6 months was obtained in 184 lesions (80%). At follow-up, the luminal late loss was similar in the 2 groups (0.91 +/- 0.77 mm in group 1 vs 0.88 +/- 0.80 mm in group 2, P = .79), and the angiographic restenosis rates were 11.0% in group 1 and 16.1% in group 2 (P = .31). The occurrence rates of MACE at 12 months were 9.1% in group 1 and 10.4% in group 2 (P = .73). CONCLUSIONS The initial and long-term outcomes of the carbon ion-implanted stent were excellent. However, it did not improve long-term outcomes vs the bare metal stent.
منابع مشابه
بررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385
Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...
متن کاملComparison of a drug-eluting balloon first and then bare metal stent with a drug-eluting stent for treatment of de novo lesions: study protocol of a randomized controlled trial
BACKGROUND The use of a drug-eluting balloon for the treatment of de novo coronary artery lesions remains to be evaluated. A previous trial in patients with stable and unstable angina comparing a bare metal stent mounted on a drug-eluting balloon with a sirolimus-eluting stent failed to meet the prespecified non-inferiority criteria versus the sirolimus-eluting stent. The stent struts of a bare...
متن کاملInterventional Cardiology Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
Background—Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus....
متن کاملThree overlapping septal occlusion devices to treat residual shunting across an atrial septal defect.
Saunamäki K, Krusell LR, Jensen GVH, Bøtker HE, Lassen JF, Andersen HR, Thayssen P, Galløe A, van Weert A, for the SCANDSTENT Investigators. A randomized multicenter comparison of sirolimus versus bare metal stent implantation in complex coronary artery lesions. Results from the SCANDSTENT trial. J Am Coll Cardiol 2006;47:449–455. 8. Tsuchida K, Colombo A, Lefèvre T, Oldroyd KG, Guetta V, Guagl...
متن کاملCoronary artery disease evolution in bare-metal stent implantation: safety and efficacy of REBELTM platinum–chromium coronary stent system
2014 Coronary artery disease affects over 5,000,000 people worldwide. Despite technology evolution and extension of indications of drug-eluting and bioresorbable stents, bare-metal stents play an important role to treat single lesions less than 15 mm of length and/or greater than 2.5 mm of diameter. The REBELTM stent is made from a new platinum–chromium alloy combined with a customized stent ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American heart journal
دوره 149 2 شماره
صفحات -
تاریخ انتشار 2005